Chapter 2: Getting started
CPU Fan Min. Duty Cycle(%) [20]
Use the <+> and <-> keys to adjust the minimum CPU fan duty cycle. The values
range from 20% to 100%. When the CPU temperature is under the lower limit, the CPU
fan will operate at the minimum duty cycle.
2.7.5 Chassis Fan 1/2/3/4 Q-Fan Control [Enabled]
[Disabled] Disables the Chassis fan 1/2/3/4 Q-Fan control feature.
[Enabled] Enables the Chassis fan 1/2/3/4 Q-Fan control feature.
Chassis Fan 1/2/3/4 Speed Low Limit [600 RPM]
This item appears only when you enable the Chassis Fan Q-Fan Control feature and allows
you to disable or set the chassis fan warning speed.
Conguration options: [Ignore] [200RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM]
Chassis Fan 1/2/3/4 Prole [Standard]
This item appears only when you enable the Chassis Fan 1/2/3/4 Q-Fan Control feature and
allows you to set the appropriate performance level of the chassis fan 1/2/3/4.
[Standard] Sets to [Standard] to make the chassis fan automatically adjust depending
on the chassis temperature.
[Silent] Sets to [Silent] to minimize the fan speed for quiet chassis fan operation.
[Turbo] Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] Sets to [Manual] to assign detailed fan speed control parameters.
The following four items appear only when you set Chassis Fan 1/2/3/4 Prole to [Manual].
Chassis Fan 1/2/3/4 Upper Temperature [70]
Use the <+> and <-> keys to adjust the upper limit of the Chassis temperature. The
values range from 40ºC to 75ºC.
Chassis Fan 1/2/3/4 Max. Duty Cycle(%) [100]
Use the <+> and <-> keys to adjust the maximum chassis fan 1/2/3/4 duty cycle. The
values range from 60% to 100%. When the chassis temperature reaches the upper
limit, the chassis fan 1/2/3/4 will operate at the maximum duty cycle.
Chassis Fan 1/2/3/4 Lower Temperature [40]
Displays the lower limit of the chassis temperature.
CHASSIS Fan 1/2/3/4 Min. Duty Cycle(%) [60]
Use the <+> and <-> keys to adjust the minimum chassis fan duty cycle. The values
range from 60% to 100%. When the chassis temperature is under 40ºC, the chassis
fan will operate at the minimum duty cycle.
2.7.6 Anti Surge Support [Enabled]
This item allows you to enable or disable the Anti Surge function. Conguration options:
[Disabled] [Enabled]