GigaX2024BUser ManualLayer 2 Managed Switch
GigaX2024B L2 Managed Switch User Manualviii5.3.12 Traffic control ... 665.
88GigaX2024B L2 Managed Switch User ManualNIC Network Interface Card An adapter card that plugs into your computer and provides the physical inter
89 GigaX2024B L2 Managed Switch User ManualSNMP Simple Network Management Protocol The TCP/IP protocol used for network management.STP Spanning Tre
90GigaX2024B L2 Managed Switch User Manualthe TTL reaches zero, the packet is discarded.twisted pair The ordinary copper telephone wiring long
GigaX2024B L2 Managed Switch User Manualix5.3.18 SNMP ... 715.3
GigaX2024B L2 Managed Switch User Manualx6.2 Subnet masks ... 777 Trouble
1 GigaX2024B L2 Managed Switch User Manual1 IntroductionCongratulations on becoming the owner of the ASUS GigaX2024B Layer 2 managed switch!
2GigaX2024B L2 Managed Switch User Manual• Enterprise MIB for PSU, fan, and system temperature, voltage• Telnet/SSH remote login• TFTP for firmware
3 GigaX2024B L2 Managed Switch User Manual2 Getting to know the GigaX2024B2.1 Package contentsThe GigaX2024B switch package comes with the fol
4GigaX2024B L2 Managed Switch User Manual2.2 Front panelThe front panel includes 24 RJ-45 10/100Base-T ports, two 10/100/1000Base-T ports, two SPF
5 GigaX2024B L2 Managed Switch User Manual2.3 Rear panelThe switch rear panel contains the fan modules, a power connector and one RPS port.Figure
6GigaX2024B L2 Managed Switch User Manual3 Quick start guideThis section provides the basic instructions to set up the switch environment. Refer
7 GigaX2024B L2 Managed Switch User Manual3.2.2 Connect to the computers or a LANYou can use Ethernet cable to connect computers, hubs and other s
E2403December 2005 V1 Copyright © 2005 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software de
8GigaX2024B L2 Managed Switch User ManualTable 4. LED IndicatorsNo. LED Description1 System Solid green indicates that the switch is turned on. If thi
9 GigaX2024B L2 Managed Switch User Manual5. Type “login” to access the command line interface. The default user name is “admin”. Skip the password by
10GigaX2024B L2 Managed Switch User Manual Figure 5. Console setup3.3.2 Setting up through the Web interfaceTo connect your PC to the switch, your
11 GigaX2024B L2 Managed Switch User ManualEnter your user name and password, and then click OK to enter the configuration Manager. Use the following d
12GigaX2024B L2 Managed Switch User Manual4 Management with the Web InterfaceThe switch provides Web pages that allow switch management thr
13 GigaX2024B L2 Managed Switch User ManualFigure 9. Home page4.2 Functional layoutThe web-based configuration page consists of three separate fram
14GigaX2024B L2 Managed Switch User ManualThe menu items, as shown in Figure 12, contains all the features available for switch configuration. These fe
15 GigaX2024B L2 Managed Switch User Manual4.3 System pagesSystem pages include management, IP setup, administration, reboot, and firmware u
16GigaX2024B L2 Managed Switch User Manual Warning WarningFigure 14. IP Setup4.3.3 Reboot The Reboot page contains a Reboot button. Clicking the b
17 GigaX2024B L2 Managed Switch User Manual4.4 Physical interface The Physical Interface shows the realtime Ethernet port status. You can configur
GigaX2024B L2 Managed Switch User ManualiFederal Communications Commission StatementThis device complies with Part 15 of the FCC Rules. Operation is s
18GigaX2024B L2 Managed Switch User ManualFigure 17. Physical interface - runtime status
19 GigaX2024B L2 Managed Switch User Manual4.5 BridgeThe Bridge page group contains layer 2 configurations, like link aggregation, STP.4.5.1 Sp
20GigaX2024B L2 Managed Switch User Manual4.5.1.2 Current rootsIt shows the information of current root bridge which include • Instance ID • The
21 GigaX2024B L2 Managed Switch User Manual4.5.1.3 Bridge parametersThe spanning-tree parameters of BPDU transmission can be configured on this pan
22GigaX2024B L2 Managed Switch User Manual4.5.1.4 Port parametersThis page contains a display window to show the current configuration for each por
23 GigaX2024B L2 Managed Switch User Manual4.5.1.5 Runtime statusThis page contains a display window to show the current status for each port.Figu
24GigaX2024B L2 Managed Switch User ManualNoteAll the ports in the link aggregation group MUST operate in full duplex mode at the same speed.All th
25 GigaX2024B L2 Managed Switch User Manual4.5.3 LACPThe page configures the LACP group (port trunking). The switch provides maximum 32 l
26GigaX2024B L2 Managed Switch User ManualNote4.5.4 MirroringMirroring, together with a network traffic analyzer, helps you monitor network traffics
27 GigaX2024B L2 Managed Switch User Manual4.5.5 Static multicastThis page can add multicast addresses into the multicast table. The switc
GigaX2024B L2 Managed Switch User ManualiiASUS contact informationASUSTeK COMPUTER INC. (Asia-Pacific)Address: 150 Li-Te Road, Peitou, Taipei, TaiwanG
28GigaX2024B L2 Managed Switch User Manual4.5.6 IGMP snoopingIGMP snooping helps reduce the multicast traffics on the network by allowing the IG
29 GigaX2024B L2 Managed Switch User Manual4.5.7 Traffic controlTraffic control prevents the switch bandwidth from flooding packets including b
30GigaX2024B L2 Managed Switch User Manual4.5.9 Static addressesYou can add a MAC address into the switch address table. The MAC address added by
31 GigaX2024B L2 Managed Switch User Manual4.5.10 VLAN configurationYou can set up to 254 VLAN groups and show VLAN group in this page. VLAN1 is a
32GigaX2024B L2 Managed Switch User Manual4.5.11 GVRPGeneric Attribute Registration Protocol (GARP) VLAN Registration Protocol (GVRP) is an a
33 GigaX2024B L2 Managed Switch User ManualFigure 33. GARP timer4.5.12 QoS and CoS4.5.12.1 802.1p priorityEight egress queues on all switch po
34GigaX2024B L2 Managed Switch User ManualFigure 34. 802.1p Priority4.5.12.2 CoS queue mappingThe switch supports four egress queues for each
35 GigaX2024B L2 Managed Switch User Manual4.5.12.3 QoS bandwidthSome VLAN tag related field settings for each port are included in this page. It i
36GigaX2024B L2 Managed Switch User ManualFigure 37. Community table4.6 SNMPThis group offers the SNMP configuration including Community Tab
37 GigaX2024B L2 Managed Switch User Manual4.6.2 Host tableThis page links host IP address to the community name that is entered in Co
GigaX2024B L2 Managed Switch User ManualiiiTable of content1 Introduction ...
38GigaX2024B L2 Managed Switch User Manual4.6.4 SNMPv3 VGU tableThereʼre two articles presenting the new security features defined by SNMPv3. The
39 GigaX2024B L2 Managed Switch User Manual4.6.4.2 VACM groupVACM Group is used to configure the information of SNMPV3 VACM Group. Group Name: ente
40GigaX2024B L2 Managed Switch User Manual4.6.4.3 USM userUSM User is used to configure the information of SNMPV3 USM User. User Name: User name of
41 GigaX2024B L2 Managed Switch User Manual4.7 Filter pagesThe switch can filter certain traffic types according to packet header information from L
42GigaX2024B L2 Managed Switch User ManualThe Filter Rule page provides options for rule modes, one is MAC rule and the other is IP rule. If you did n
43 GigaX2024B L2 Managed Switch User ManualNote4.7.2 Filter attachA filter set is idle if you did not attach it to any ingress port. Use the Filter
44GigaX2024B L2 Managed Switch User Manual4.8 SecurityThe switch supports the 802.1x port-based security feature. Only authorized hosts are
45 GigaX2024B L2 Managed Switch User Manualrequest from the switch, the switch waits upon this time period before sending another authentic
46GigaX2024B L2 Managed Switch User Manual4.8.2 Dial-in userDial-in User is used to define users in the local database of the switch. User Name: Ne
47 GigaX2024B L2 Managed Switch User ManualNote4.8.3 RADIUSIn order to use external RADIUS server, the following parameters are required to be set
GigaX2024B L2 Managed Switch User Manualiv4.2.2 Commonly used buttons and icons ... 144.3 System pages
48GigaX2024B L2 Managed Switch User Manual4.8.4 Port securityThe switch also supports port security feature. It enables a systemʼs admin
49 GigaX2024B L2 Managed Switch User ManualFigure 50. Port security4.8.4.2 Port statusThis page shows the current port status, MAC address
50GigaX2024B L2 Managed Switch User ManualFigure 51. Port status4.8.4.3 Secure MAC addressSecure MAC Address offers three functions for user manag
51 GigaX2024B L2 Managed Switch User Manual4.9 Traffic chartThe Statistics Chart pages provide network flow in different charts. You can spec
52GigaX2024B L2 Managed Switch User Manual4.9.2 Error group chartSelecting the Port and display Color, then clicking the Draw, the statis
53 GigaX2024B L2 Managed Switch User Manual4.10 Cable diagnosisTo analysis the cabling plant for the common cable problems, such as open
54GigaX2024B L2 Managed Switch User Manual5 Console interfaceThis chapter describes how to use console interface to configure the switch. The switc
55 GigaX2024B L2 Managed Switch User ManualFigure 59. Boot ROM command mode5.1.2 Boot ROM commandsThe followings are two types of boot ROM command
56GigaX2024B L2 Managed Switch User ManualNote5.2 Login and logoutTo enter the CLI mode, you have to give a valid user name and password. As the
57 GigaX2024B L2 Managed Switch User ManualCLI Syntax: copy startup-config tftp: URLExample: ASUS# copy startup-config tftp: 192.168.8.56/gx2024b.cfg5.3
GigaX2024B L2 Managed Switch User Manualv4.6.3 Trap setting ... 374.6
58GigaX2024B L2 Managed Switch User Manual5.3.3.5 endThis command let user end current mode and down to enable mode.CLI Syntax: endExample: ASUS#
59 GigaX2024B L2 Managed Switch User Manual5.3.3.10 System LocationDisplays the physical location of the switch. This is an RFC-1213 defined MIB ob
60GigaX2024B L2 Managed Switch User Manual5.3.3.14 reload default-config fileUse this command to copy a default-config file to replace the current one
61 GigaX2024B L2 Managed Switch User Manual5.3.4.1 Interface modeUse the auto-negotiation configuration command on the switch to set aut
62GigaX2024B L2 Managed Switch User ManualNoteNote5.3.5 IP interface5.3.5.1 show vlan name stringUse the show vlan user EXEC command to
63 GigaX2024B L2 Managed Switch User Manual5.3.5.5 ip dhcp clientThis command set system interface to get ip via dhcp server.CLI Syntax: ip dhcp c
64GigaX2024B L2 Managed Switch User Manual5.3.7.2 trunk load balancingUse the aggregation-link trunk group configuration command on the switch t
65 GigaX2024B L2 Managed Switch User Manual5.3.9 Mirroring 5.3.9.1 Mirror settingThis command mirrors the source interface list traffic to the
66GigaX2024B L2 Managed Switch User Manual5.3.10.2 no mac-address-table multicastUse the no mac-address-table multicast configuration command on th
67 GigaX2024B L2 Managed Switch User Manual5.3.12.2 no storm-controlUse the no storm-control configuration command on the switch to disable the
GigaX2024B L2 Managed Switch User Manualvi5.3.1.2 Delete user ... 565.3.2
68GigaX2024B L2 Managed Switch User Manual5.3.13.4 show mac-address-table aging-timeCLI Syntax: show mac-address-table aging-timeExample: ASUS# s
69 GigaX2024B L2 Managed Switch User Manual5.3.15.3 name stringUse the name string command to create vlan entry with string on the switch.CLI Synt
70GigaX2024B L2 Managed Switch User Manual5.3.16.3 show gvrp configurationTo show gvrp configuration IFNAME status.CLI Syntax: show gvrp interface I
71 GigaX2024B L2 Managed Switch User Manual5.3.17.5 qos ingress bandwidthThis command used to set the Qos bandwidth informational parameter for th
72GigaX2024B L2 Managed Switch User Manual5.3.19.2 filter setThis command define an extended MAC access list using a name , and enter access-list co
73 GigaX2024B L2 Managed Switch User Manual5.3.20.2 dot1x max-reqUse the dot1x max-req interface configuration command on the switch to set the max
74GigaX2024B L2 Managed Switch User Manual5.3.22 RADIUS 5.3.22.1 RADIUS settingsThis command sets the radius server ip, radius key, and radius
75 GigaX2024B L2 Managed Switch User Manual5.3.23.3 switchport port-securityThis command used to set the port security configuration, and MAC addre
76GigaX2024B L2 Managed Switch User ManualNote6 IP Addresses, network masks, and subnets6.1 IP addressesThis section pertains only t
77 GigaX2024B L2 Managed Switch User ManualFollowing are examples of valid IP addresses:Class A: 10.30.6.125 (network = 10, host = 30.6.125)Class B: 1
GigaX2024B L2 Managed Switch User Manualvii5.3.5.1 show vlan name string ... 625.3.5.2 Cre
78GigaX2024B L2 Managed Switch User ManualNoteSubnet masks are used to define subnets (what you get after dividing a network into smaller pieces). A
79 GigaX2024B L2 Managed Switch User Manual7 TroubleshootingThis section gives instructions for using several IP utilities to diagnose problems. A
80GigaX2024B L2 Managed Switch User ManualIf the target computer cannot be located, you will receive the message “Request timed out.”Using the ping co
81 GigaX2024B L2 Managed Switch User Manual WarningThere may be several addresses associated with an Internet name. This is common for web sit
82GigaX2024B L2 Managed Switch User ManualFigure 65. Detaching the fan from the module5. Fasten the new fan with the screws that you removed earlier.
83 GigaX2024B L2 Managed Switch User Manual7.3 Simple fixesThe following table lists some common problems that you may encounter when installing or
84GigaX2024B L2 Managed Switch User ManualProblem Suggested ActionPCs cannot display web configuration pages.1.The switch is powered up and the connec
85 GigaX2024B L2 Managed Switch User Manual8 Glossary10BASE-T A designation for the type of wiring used by Ethernet networks with a d
86GigaX2024B L2 Managed Switch User Manualwill accept and/or reject. Filtering rules are defined to operate on an interface (or multiple interfaces)
87 GigaX2024B L2 Managed Switch User Manualthat identifies the particular network the host belongs to, and a host ID uniquely identifying the host itse
Comments to this Manuals