Chapter 2: Hardware setup2-22
3. Firmly pull the power supply
module out of the system chassis.
4. Firmly push the new power supply
module into the chassis until the
latch locks to the server chassis.
If you install two or more nodes, please install both the power supply
modules.
The system automatically combines the two power supply modules as a
single one. The combined output power varies with input voltages. Refer to
the table below for details.
Input Voltage Max. Output Power (Watt) per PSU
100–120Vac, 12–10A, 50–60Hz 1000W
120–140Vac, 12–10A, 50–60Hz 1200W
180–240Vac, 10.5–8A, 50–60Hz 1620W
To enable the hot-swap feature (redundant mode), keep the total power
consumption of the installed nodes under the maximum output power of an
individual power supply module.
For steady power input, use only the power cables that come with the
server system package.