Chapter 6: Technology Background
95
RAID 1 – Mirror
When a logical drive is mirrored, identical data is written to a pair of physical
drives, while reads are performed in parallel. The reads are performed using
elevator seek and load balancing techniques where the workload is distributed in
the most efficient manner. Whichever drive is not busy and is positioned closer to
the data will be accessed first.
With RAID 1, if one physical drive fails or has errors, the other mirrored physical
drive continues to provide fault tolerance. Moreover, if a spare drive is present,
the spare drive will be used as the replacement drive and data will begin to be
mirrored to it from the remaining good drive.
Figure 2. RAID 1 mirrors identical data across to two physical drives
Due to the data redundancy of mirroring, the capacity of the logical drive equals
the size of the smallest physical drive. For example, two 100 GB physical drives
which have a combined capacity of 200 GB instead would have 100 GB of usable
storage when set up in a mirrored logical drive. Similar to RAID 0 striping, if
physical drives of different capacities are used, there will also be unused capacity
on the larger drive.
RAID 1 logical drives on the AMD SB6xx/SB7xx Controller consist of two
physical drives. You can create multiple RAID 1 logical drives on the same
Controller.
Data Mirror
physical drives