2U Rackmount ServerRS720-E7/RS12RS720-E7/RS12-EUser Guide
xReferencesRefer to the following sources for additional information, and for product and software updates.1. ASUS Server Web-based Management (ASWM)
5-32 Chapter 4: BIOS setupData Bits [8]Conguration options: [7] [8]Parity [None]A parity bit can be sent with the data bits to detect some transmissi
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-33Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS)Console Redirection [Disable
5-34 Chapter 4: BIOS setup5.4.15 ME Subsystem Intel ME Subsystem Conguration ME BIOS Interface Version 1.2 ME Version 2.1.5.64 ME FW Status Va
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-355.4.17 Runtime Error Logging Runtime Error Logging Support [Disabled]Runtime Error Logging Support [Disable
5-36 Chapter 4: BIOS setup5.5 Server Mgmt menuThe Server Mgmt menu displays the server mgmt status, and allows you to change the settings.Aptio Setup
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-375.5.1 System Event LogAptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Ser
5-38 Chapter 4: BIOS setup5.5.2 BMCnetworkcongurationAptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mg
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-395.6 Event Logs menuThe Event Logs allows you to change or view the event log settings.Aptio Setup Utility - C
5-40 Chapter 4: BIOS setupWhen Log is Full [Do Nothing]Allows to choose options for reactions to a full Smbios Event Log. Conguration options: [Do No
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-415.7 Boot menuThe Boot menu items allow you to change the system boot options.Number of seconds to wait for se
1-This chapter describes the general features of the chassis kit. It includes sections on front panel and rear panel specications.Chapter 1Product i
5-42 Chapter 4: BIOS setupBoot Device Seeking [Endless PXE][Endless PXE] Continuous seek remote boot image until boot image found or user abort (pres
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-435.8 Monitor menuThe Monitor menu displays the system temperature/power status, and allows you to change the f
5-44 Chapter 4: BIOS setupFAN Speed Control [Generic Mode]Allows you to congure the ASUS Smart Fan feature that smartly adjusts the fan speeds for mo
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-45User PasswordIf you have set a user password, you must enter the user password for accessing the system. The U
5-46 Chapter 4: BIOS setup5.11 Exit menuThe Exit menu items allow you to save or discard your changes to the BIOS items.Pressing <Esc> does not
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-47Boot OverrideThese items displays the available devices. The device items that appears on the screen depends o
5-48 Chapter 4: BIOS setup
3-This chapter provides instructions for setting up, creating and conguring RAID sets using the available utilities.Chapter 6RAIDconguration
6-2 Chapter 6: RAID conguration6.1 Setting up RAIDThe motherboard comes with the Intel® C202 chipset that supports the following SATA RAID solutions
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-36.1.3 RAID controller selectionYou can choose either the LSI Software RAID Conguration Utility or the Intel M
Chapter 1: Product introduction1-2*ASUS System Web-based ManagementIf any of the above items is damaged or missing, contact your retailer.1.1 System
6-4 Chapter 6: RAID conguration3. The utility main window appears. Use the arrow keys to select an option from the Management Menu and then press &l
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-56.2.1 Creating a RAID setThe LSI Software RAID Conguration Utility allows you to create a RAID 0, RAID 1, or
6-6 Chapter 6: RAID conguration3. Select all the drives required for the RAID set, and then press <F10> to congure array setting.4. Press &l
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-75. Press <F10> again, the virtual drive information appears including a Virtual Drive menu that allows y
6-8 Chapter 6: RAID conguration8. Select Units from the Virtual Drive sub-menu, and then press <Enter>.9. Select the units for virtual drive
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-912. When nished setting the selected virtual drive conguration, select Accept from the menu, and then press
6-10 Chapter 6: RAID congurationUsingNewCongurationWhen a RAID set already exists, using the NewConguration command erases the existing RAID con
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-116.2.2 AddingorviewingaRAIDcongurationYou can add a new RAID conguration or view an existing congurati
6-12 Chapter 6: RAID conguration6.2.3 Initializing the virtual drivesAfter creating the RAID set(s), you must initialize the virtual drives. You may
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-133. Press <F10> to start initialization. When prompted, select Yes from the Initialize? dialog box, and
ASUS RS720-E7/RS12; RS720-E7/RS12-E 1-31.3 SystemspecicationsThe ASUS RS720-E7/RS12 and RS720-E7/RS12-E feature the ASUS Z9PE-D16 server board. The
6-14 Chapter 6: RAID congurationUsingtheObjectscommandTo initialize the virtual drives using the Objects command1. From the Management Menu, sele
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-153. Select Initialize from the pop-up menu, and then press <Enter> to start initialization.Management Me
6-16 Chapter 6: RAID conguration6.2.4 Rebuilding failed drivesYou can manually rebuild failed hard disk drives using the Rebuild command in the Mana
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-173. After selecting the drive to rebuild, press <F10>. When prompted, press <Y> to rebuild the dri
6-18 Chapter 6: RAID conguration6.2.5 Checking the drives for data consistencyYou can check and verify the accuracy of data redundancy in the select
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-193. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press <
6-20 Chapter 6: RAID congurationUsingtheObjectscommandTo check data consistency using the Objects command1. From the Management Menu, select Obje
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-216.2.6 DeletingaRAIDcongurationTo delete a RAID conguration1. From the Management Menu, select Congure
6-22 Chapter 6: RAID conguration6.2.7 Selecting the boot drive from a RAID setYou must have created a new RAID conguration before you can select th
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-236.2.8 Enabling WriteCacheYou may manually enable the RAID controller’s WriteCache option after creating a RAI
Chapter 1: Product introduction1-4*Specicationsaresubjecttochangewithoutnotice.Model Name RS720-E7/RS12 RS720-E7/RS12-EStorageSAS ControllerOp
6-24 Chapter 6: RAID conguration6.3 Intel® Rapid Storage Technology enterprise SCU/SATA Option ROM UtilityThe Intel® Rapid Storage Technology enter
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-25Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corpora
6-26 Chapter 6: RAID conguration[ CREATE VOLUME MENU ][ HELP ]Enter a unique volume name that has no special characters and is 16 characters or less.
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-276. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and t
6-28 Chapter 6: RAID conguration5. Use the up/down arrow keys to select a drive, press <TAB> to select a Master disk, and then press <SPACE
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-296.3.3 Deleting a RAID setTake caution when deleting a RAID set. You will lose all data on the hard disk drive
6-30 Chapter 6: RAID conguration6.3.4 Resetting disks to Non-RAIDTake caution before you reset a RAID volume hard disk drive to non-RAID. Resetting
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-31Select a destination disk with the same size as the original hard disk.[ DEGRADED VOLUME DETECTED ][↑↓]-Previo
6-32 Chapter 6: RAID conguration3. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is c
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-336.3.7 Setting the Boot array in the BIOS Setup UtilityYou can set the boot priority sequence in the BIOS for
ASUS RS720-E7/RS12; RS720-E7/RS12-E 1-51.4 Front panel featuresThe barebone server displays a simple yet stylish front panel with easily accessible f
6-34 Chapter 6: RAID congurationYou can click Rescan to re-scan any attached hard disks.6.4 Intel® Rapid Storage Technology enterprise Utility (Win
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-356.4.1 Creating a RAID setTo create a RAID set1. From the utility main menu, select Create Volume and select
6-36 Chapter 6: RAID conguration6. Conrm volume creation, than click Create Volume to continue.This process could take a while depending on the num
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-376.4.2 Change Volume TypeWhen you are nished to create a RAID set, you can view or change related items in th
6-38 Chapter 6: RAID conguration6.4.3 Delete volumeTake caution when deleting a volume. You will lose all data on the hard disk drives.Back up data
ASUS RS720-E7/RS12; RS720-E7/RS12-E 6-396.4.4 PreferencesSystem PreferencesAllow you set to show the notication area icon and show system informatio
6-40 Chapter 6: RAID conguration
Chapter 7Driver installationThis chapter provides instructions for installing the necessary drivers for different system components.
7-2 Chapter 7: Driver installation7.1 RAID driver installationAfter creating the RAID sets for your server system, you are now ready to install an op
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-36. Locate the RAID driver and place a blank, high-density oppy disk to the oppy disk drive.7. Press <Ent
Chapter 1: Product introduction1-6• The ports for the PS/2 keyboard, PS/2 mouse, USB, VGA, and Gigabit LAN do not appear on the rear panel if mother
7-4 Chapter 7: Driver installationTo create a RAID driver disk in Windows® environment1. Start Windows®.2. Place the motherboard support DVD into
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-57.1.2 Installing the RAID controller driverDuring Windows® Server 2008 OS installationTo install the RAID cont
7-6 Chapter 7: Driver installation4. A message appears, reminding you to insert the installation media containing the driver of the RAID controller d
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-73. Select Yes using the <Tab> key when asked if you have the driver disk, then press <Enter>.Main
7-8 Chapter 7: Driver installation5. When asked if you will load additional RAID controller drivers, select No, then press <Enter>.More Driver
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-93. Select Yes using the <Tab> key when asked if you have the driver disk, then press <Enter>.Main
7-10 Chapter 7: Driver installation4. You have multiple devices which could serve as source for a driver disk. Choose one you like to use and select
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-11SUSE Linux 11 OSTo install the LSI MegaRAID controller driver when installing SUSE Linux Enterprise Server OS:
7-12 Chapter 7: Driver installation4. Insert the RAID driver disk to the oppy disk drive. Type the command acpi=off apic=bigsmp brokenmodules=ahci i
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-137. Select Back and follow the onscreen instructions to nish the installation.6. The drivers for the RAID co
ASUS RS720-E7/RS12; RS720-E7/RS12-E 1-71.6 Internal featuresThe barebone server includes the basic components as shown.The barebone server does not i
7-14 Chapter 7: Driver installation7.2 Intel® chipset device software installationThis section provides the instructions on how to install the Intel
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-155. Select Yes to accept the terms of the License Agreement and continue the process.6. Read the Readme File
7-16 Chapter 7: Driver installation7.3 Intel@ Network Connections Software installationThis section provides the instructions on how to install the
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-175. Click Next when the Intel(R) Network Connections–InstallShield Wizard window appears. 6. Toggle I accept
7-18 Chapter 7: Driver installation8. Follow the screen instructions to complete installation.9. When nished, press Finish to continue.
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-197.4 VGA driver installationThis section provides the instructions on how to install the ASPEED Video Graphics
7-20 Chapter 7: Driver installation6. Enter the user information and click Next to continue.7. Select a setup type and click Next to continue.5. To
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-219. When the installation completes, click Finish to restart your computer before using the program.8. Click
7-22 Chapter 7: Driver installation7.5 Intel® C600 Series Chipset SAS RAID (SATA mode) DriversThis section provides the instructions on how to insta
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-237.6 Microsoft .NET Framework 3.5 SP1This section provides the instructions on how to install the Microsoft .N
Chapter 1: Product introduction1-81.7 LED information1.7.1 Front panel LEDsMessage LEDLAN2/4 LEDHDD Access LEDLAN1/3 LEDPower LEDLocation LEDLED Ic
7-24 Chapter 7: Driver installation7.7 Intel® Rapid Storage Technology enterprise 3.0 installationThis section provides the instructions on how to i
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-255. Read the Warning message and click Next to continue.6. Read the License Agreement and click Yes to contin
7-26 Chapter 7: Driver installation9. Select Yes, I want to restart my computer now and click Finish to restart your computer before using the progra
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-277.8 Intel® I350 Gigabit Adapters Driver installationThis section provides the instructions on how to install
7-28 Chapter 7: Driver installation5. Click I accept the terms in the license agreement and then click Next to continue.4. When the Intel® PRO Netwo
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-296. Select the programs you want to install and click Next to continue. 7. Click Install to start the install
7-30 Chapter 7: Driver installation8. The programs you select are being installed.9. Click Finish to nish the installation.
ASUS RS720-E7/RS12; RS720-E7/RS12-E 7-317.9 Management applications and utilities installationThe support DVD that came with the motherboard package
7-32 Chapter 7: Driver installation7.9.3 Utilities menuThe Utilities menu displays the software applications and utilities that the motherboard suppo
ASUS RS720-E7/RS12; RS720-E7/RS12-E A-1ASUS contact informationASUSTeK COMPUTER INC.Address 15 Li-Te Road, Peitou, Taipei, Taiwan 11259Telephone
ASUS RS720-E7/RS12; RS720-E7/RS12-E 1-91.7.3 HDD status LEDSATA/SAS HDD LED DescriptionHDD Activity LED (Green)OFF HDD not presentON HDD present, no
ASUS contact informationASUS COMPUTER INTERNATIONAL (America)Address 800 Corporate Way, Fremont, CA 94539, USAFax +1-510-608-4555Web site h
iiCopyright © 2012 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and software described in it, may be repro
Chapter 1: Product introduction1-10
2-This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.Chapter 2Hardware setup
Chapter 2: Hardware setup2-22.1 Chassis cover2. Firmly hold the cover and slide it toward the rear panel for about half an inch until it is disenga
2-3ASUS RS720-E7/RS12; RS720-E7/RS12-E2.2.1 Installing the CPUTo install a CPU:1. Locate the CPU socket on the motherboard.2.2 Central Processing U
Chapter 2: Hardware setup2-42. Press the left load lever with your thumb (A), then move it to the left (B) until it is released from the retention t
2-5ASUS RS720-E7/RS12; RS720-E7/RS12-EIH7. Remove the PnP cap (H) from the CPU socket and then close the load plate (I).GF5. Push the left load lev
Chapter 2: Hardware setup2-6KJ8. Push down the right load lever (J), ensuring that the edge of the load plate is xed by the lever (K).9. Insert th
2-7ASUS RS720-E7/RS12; RS720-E7/RS12-EThe Thermal Interface Material is toxic and inedible. DO NOT eat it. If it gets into your eyes or touches your s
Chapter 2: Hardware setup2-82. Twist each of the four screws with a Philips (cross) screwdriver just enough to attach the heatsink to the motherboar
2-9ASUS RS720-E7/RS12; RS720-E7/RS12-E4. Use the three screws that including in the package, tighten them one by one to completely secure the airduct
iiiContentsNotices ... viiSafety information ...
Chapter 2: Hardware setup2-102.3 System memory2.3.1 OverviewThe motherboard comes with eight (per CPU) Double Data Rate 3 (DDR3) Dual Inline Memory
2-11ASUS RS720-E7/RS12; RS720-E7/RS12-E• Always install DIMMs with the same CAS latency. For optimum compatibility, we recommend that you obtain memo
Chapter 2: Hardware setup2-122.3.3 Installing a DIMM3. Hold the DIMM by both of its ends, then insert the DIMM vertically into the socket. Apply fo
2-13ASUS RS720-E7/RS12; RS720-E7/RS12-E2.4 Hard disk drivesThe hard disk drive installed on the drive tray connects to the motherboard SATA/SAS ports
Chapter 2: Hardware setup2-145. Carefully insert the drive tray and push it all the way to the depth of the bay until just a small fraction of the t
2-15ASUS RS720-E7/RS12; RS720-E7/RS12-E2.5 Expansion slotsIn the future, you may need to install expansion cards. The following subsections describe
Chapter 2: Hardware setup2-16* These IRQs are usually available for ISA or PCI devices.2.5.3 Interrupt assignmentsStandard Interrupt assignmentsWhen
2-17ASUS RS720-E7/RS12; RS720-E7/RS12-E2.5.4 PCI Express x16 slots (x16 link)The onboard PCIE 3 and 5 provide one x16 Gen3 link to CPU2; The onboard
Chapter 2: Hardware setup2-182.6 Cable connectionsPre-connected system cables1. 24-pin EATX power connector (from power supply to motherboard)2. 8
2-19ASUS RS720-E7/RS12; RS720-E7/RS12-E2.7 SATA/SAS backplane cablingRS720-E7/RS12MODE_SEL2: Set to pin 1-2 to enable SGPIO function (default).SGPIO1
ivContents2.8.2 Redundant power supply module ... 2-222.8.3 Installing ASUS PIKE RAID card ...
Chapter 2: Hardware setup2-20Connects a 8-pin plug from power supplyConnects to the SAS connectors on the motherboard. With all eight SAS cables con
2-21ASUS RS720-E7/RS12; RS720-E7/RS12-E2.8 Removable/optional componentsYou may need to remove previously installed system components when installing
Chapter 2: Hardware setup2-222.8.2 Redundant power supply moduleTo install a second redundant power supply module:1. Remove the redundant power sup
2-23ASUS RS720-E7/RS12; RS720-E7/RS12-E2.8.3 Installing ASUS PIKE RAID cardFollow the steps below to install an optional ASUS RAID card on your mothe
Chapter 2: Hardware setup2-242.8.4 Installing ASMB6 series management board(Default)Follow the steps below to install an ASMB6 series management boa
2-25ASUS RS720-E7/RS12; RS720-E7/RS12-E5. Insert the LAN cable plug to the DM_LAN 1 port (dedicated LAN) or LAN port 1 (shared LAN) for server manage
Chapter 2: Hardware setup2-26
2-This chapter describes how to install the optional components and devices into the barebone server.Chapter 3Installation options
Chapter 3: Installation options3-2Fixing latch3.1.1 AttachingthexinglatchestotheserverRefer to the gures below for the locations to attach t
3-3ASUS RS720-E7/RS12; RS720-E7/RS12-E1. Select a 1U space on the rack where you want to install the rack rail. A 1U space consists of three square m
vContents5.4.5 PCH SCU SAS Conguration ... 5-215.4.6 PCI Subsystem Settings ...
Chapter 3: Installation options3-4Do not install the rail kit in the following situation:DO NOT place the rail hook on a thick lip of the mounting ho
3-5ASUS RS720-E7/RS12; RS720-E7/RS12-E3.1.2 Mounting the server to the rackTo mount the server to the rack1. Place the server on the rack rails, and
Chapter 3: Installation options3-6
3-4-1This chapter includes the motherboard layout, and brief descriptions of the jumpers and internal connectors.Chapter 4Motherboard info
4-2 Chapter 4: Motherboard information4.1 Motherboard layouts
ASUS RS720-E7/RS12; RS720-E7/RS12-E 4-3Layout contentsJumpers Page1. Clear RTC RAM (CLRTC1) 4-32. VGA controller setting (3-pin VGA_SW1)4-43. LAN c
4-4 Chapter 4: Motherboard information4.2 Jumpers1. Clear RTC RAM (CLRTC1)This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. Yo
ASUS RS720-E7/RS12; RS720-E7/RS12-E 4-52. VGA controller setting (3-pin VGA_SW1)This jumper allows you to enable or disable the onboard VGA controlle
4-6 Chapter 4: Motherboard information4. LSIMegaRAIDorIntelRSTeselectionjumper(3-pinRAID_SEL1)This jumper allows you to select the PCH SATA R
ASUS RS720-E7/RS12; RS720-E7/RS12-E 4-76. DDR3 thermal event setting (3-pin DIMMTRIP1)This jumper allows you to enable/disable DDR3 DIMM thermal sens
viContents6.2.6 Deleting a RAID conguration ... 6-216.2.7 Selecting the boot drive from a RAID set ...
4-8 Chapter 4: Motherboard information4.3 Internal connectors1. Serial ATA 6.0/3.0 Gb/s connectors (7-pin SATA6G_1-2 [Blue], and 7-pin SATA3G_3-6
ASUS RS720-E7/RS12; RS720-E7/RS12-E 4-93. USB connectors (10-1 pin USB34, USB56; A-Type USB10)These connectors are for USB 2.0 ports. Connect the USB
4-10 Chapter 4: Motherboard information• DO NOT forget to connect the fan cables to the fan connectors. Insufcient air ow inside the system may dam
ASUS RS720-E7/RS12; RS720-E7/RS12-E 4-117. Serial General Purpose Input/Output connectors (8-1 pin PSGPIO 1/2, ISGPIO1, SGPIO1)The SGPIO 1 connecto
4-12 Chapter 4: Motherboard information9. TPM connector (20-1 pin TPM)This connector supports a Trusted Platform Module (TPM) system, which can secur
ASUS RS720-E7/RS12; RS720-E7/RS12-E 4-1310. EATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1/EATX12V2, PSUSMB1)These connectors are for an E
4-14 Chapter 4: Motherboard information11. System panel connector (20-1 pin PANEL1)This connector supports several chassis-mounted functions.(1) Sys
ASUS RS720-E7/RS12; RS720-E7/RS12-E 4-1512. Auxiliary panel connector (20-2 pin AUX_PANEL1)This connector is for additional front panel features incl
4-16 Chapter 4: Motherboard information
This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.3-5-
viiNoticesFederal Communications Commission StatementThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two con
5-2 Chapter 4: BIOS setup5.1 Managing and updating your BIOSThe following utilities allow you to manage and update the motherboard Basic Input/Output
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-33. Press <Tab> to switch to the Drive eld.4. Press the Up/Down arrow keys to nd the USB ash disk tha
5-4 Chapter 4: BIOS setup5.1.3 BUPDATER utilityThe succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the sam
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-5 The utility veries the le, then starts updating the BIOS le.DO NOT shut down or reset the system while upd
5-6 Chapter 4: BIOS setup5.2 BIOS setup programThis motherboard supports a programmable rmware chip that you can update using the provided utility d
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-75.2.2 Menu barThe menu bar on top of the screen has the following main items:Main For changing the basic s
5-8 Chapter 4: BIOS setup5.2.3 Menu itemsThe highlighted item on the menu bar displays the specic items for that menu. For example, selecting Main s
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-95.3 Main menuWhen you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you a
5-10 Chapter 4: BIOS setup5.4 Advanced menuThe Advanced menu items allow you to change the settings for the CPU and other system devices.Take caution
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-11Socket 1 CPU InformationEnter to view socket soecic CPU Information.Enter to view socket soecic CPU Informat
viiiSafety informationElectrical Safety• Before installing or removing signal cables, ensure that the power cables for the system unit and all attach
5-12 Chapter 4: BIOS setupAdjacentCacheLinePrefetch[Enabled]This Item allows you to turn on/off prefetching of adjacent cache lines. Conguration
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-13Turbo Mode [Enabled]Conguration options: [Disabled] [Enabled] P-STATE Coordination [HW_ALL]This item allows y
5-14 Chapter 4: BIOS setup QPI Conguration Memory Conguration CPU II0 Bridge Conguration PCH Conguration Intel(R) VT for Directed I/O Conguration
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-15MemoryCongurationSupport for compatibility Revision ID(CRID) Functionality mentioned in Sandybridge bios spe
5-16 Chapter 4: BIOS setupPatrol Scrub [Disabled]Allows to Enable/Disable Patrol Scrub. Conguration options: [Disabled] [Enabled]Demand Scrub [Enable
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-17Enables/Disables Intel(R) I/O Acceleration Technology (I/OAT).Intel(R) I/OAT [Disabled]DCA Support [Enab
5-18 Chapter 4: BIOS setupPCHCongurationPCH Compatibility RID [Disabled]Support for PCH compatibility. Conguration options: [Disabled] [Enabled]Dee
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-19HighPrecisionEventTimerCongurationHigh Precision Timer [Enabled]Allows to enabled/disabled High Precision
5-20 Chapter 4: BIOS setup5.4.4 PCHSATAConguration(1)IDE Mode. (2)AHCI Mode. (3)RAID Mode.SATA Port1 Not PresentSATA Port2 ASUS DWR ATAPISATA Po
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-21S.M.A.R.T. Status Check [Enabled]S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) is a monitor
ixAbout this guideAudienceThis user guide is intended for system integrators, and experienced users with at least basic knowledge of conguring a serv
5-22 Chapter 4: BIOS setup5.4.6 PCI Subsystem SettingsIn case of multiple Option ROMs (Legacy and EFI Compatible), species what PCI option ROM to la
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-23PCI Express SettingsEnables or DisablesPCI Express Device Relaxed Ordering.PCI Express Link Register SettingsA
5-24 Chapter 4: BIOS setupPCIESlotOptionRomCongurationEnables or disables boot option for legacy mass storage device with option ROM.Legacy OpROM
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-255.4.7 OnboardLANCongurationPXE/iSCSI.Onboard LAN CongurationIntel LAN ROM Type [PXE]Intel LAN1 Enab
5-26 Chapter 4: BIOS setup5.4.8 IntelTXT(LT-SX)CongurationThe Intel TXT(LT-SX) conguration automatically detects and displays the Intel TXT(LT-SX
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-275.4.9 USBCongurationEnabled Legacy USB support. Auto option disables legacy support if no USB devices are
5-28 Chapter 4: BIOS setupEnable/Disable USB 2.0 (EHCI) Support.EHCI Controller 1 [Enabled]EHCI Controller 2 [Enabled]Rear USB #1 [E
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-295.4.11 ACPI SettingsEnables or Disables BIOS ACPI Auto Conguration.ACPI SettingsEnable ACPI Auto Conguratio
5-30 Chapter 4: BIOS setup5.4.12 WHEACongurationEnable or disable Windows Hardware Error Architecture.WHEA Support [Enabled]WHEA Support [Enabled]
ASUS RS720-E7/RS12; RS720-E7/RS12-E 5-315.4.14 Serial Port Console Redirection COM1 Console Redirection [Disabled] Console Redirection Setting
Comments to this Manuals