ASUS AP130-D5 Pedestal Server
35
Input Characteristics
A.2 Specifications
Output Characteristics
Over-Voltage Protection (OVP)
Input Voltage Range Min Nom Max
Range 1 90V 115V 140V
Range 2 180V 230V 264V
Input Frequency Range 43 Hz to 66 Hz
Maximum Input ac Current 5A max at 115Vac
3A max. at 230Vac, maximum load
Inrush Current 90A cold start
120A warm start
Efficiency 65% min. at nominal input,
maximum load
Output
Load Range Regulation Ripple
Voltage Min Max Min Max Max
+5V 1.5A 25.0A -5% +5% 50mVp-p
+12V 0.2A 8.0A -5% +5% 120mVp-p
-12V 0A 0.8A -10% +10% 120mVp-p
+5VSB 0A 2.0A -5% +5% 50mVp-p
+3V3 0A 14.0A -5% +5% 50mVp-p
Output Voltage Maximum Voltage
+5V 6.5V
+12V 15.6V
+3.3V 4.3V
NOTE
The power supply will shut down and latch off for shorting +5V,
+12V, -12V, or +3.3V. By shorting +5VSB, the power supply can
latch down or automatically recover when the fault condition is
removed.