Asus Motherboard P5MT-S Specifications Page 101

  • Download
  • Add to my manuals
  • Print
  • Page
    / 176
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 100
ASUS P5MT SeriesASUS P5MT Series
ASUS P5MT SeriesASUS P5MT Series
ASUS P5MT Series
5-15-1
5-15-1
5-1
5.1 Setting up RAID
The motherboard comes with the following RAID solutions:
P5MT modelP5MT model
P5MT modelP5MT model
P5MT model
LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID
LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID
LSI Logic Embedded SATA RAID technology embedded in the
Intel
®
ICH7R Southbridge supports up to two SATA hard disk drives and
RAID 0, RAID 1, and RAID 10 configurations.
P5MT/SCSI modelP5MT/SCSI model
P5MT/SCSI modelP5MT/SCSI model
P5MT/SCSI model
LSI Logic Embedded SATA RAIDLSI Logic Embedded SATA RAID
LSI Logic Embedded SATA RAIDLSI Logic Embedded SATA RAID
LSI Logic Embedded SATA RAID
LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller
LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller
LSI53C1020A PCI-X SCSI controller supports SCSI hard disk
drives and RAID 0, RAID 1, RAID 1-E configurations.
5.1.15.1.1
5.1.15.1.1
5.1.1
RAID definitionsRAID definitions
RAID definitionsRAID definitions
RAID definitions
RAID 0RAID 0
RAID 0RAID 0
RAID 0
(Data striping)
optimizes two identical hard disk drives to read and
write data in parallel, interleaved stacks. Two hard disks perform the same
work as a single drive but at a sustained data transfer rate, double that of
a single disk alone, thus improving data access and storage. Use of two
new identical hard disk drives is required for this setup.
RAID 1RAID 1
RAID 1RAID 1
RAID 1
(Data mirroring)
copies and maintains an identical image of data from
one drive to a second drive. If one drive fails, the disk array management
software directs all applications to the surviving drive as it contains a
complete copy of the data in the other drive. This RAID configuration provides
data protection and increases fault tolerance to the entire system. Use two
new drives or use an existing drive and a new drive for this setup. The new
drive must be of the same size or larger than the existing drive.
RAID 1RAID 1
RAID 1RAID 1
RAID 1
-E-E
-E-E
-E
(Enhanced RAID 1)
has a striped layout with each stripe unit
having a secondary (or alternate) copy stored on a different disk. You can
use three or more hard disk drives for this configuration.
RAID 0+1RAID 0+1
RAID 0+1RAID 0+1
RAID 0+1 is
data striping
and
data mirroring
combined without parity
(redundancy data) having to be calculated and written. With the RAID 0+1
configuration you get all the benefits of both RAID 0 and RAID 1
configurations. Use four new hard disk drives or use an existing drive and
three new drives for this setup.
JBODJBOD
JBODJBOD
JBOD
(Spanning)
stands for
Just a Bunch of DisksJust a Bunch of Disks
Just a Bunch of DisksJust a Bunch of Disks
Just a Bunch of Disks and refers to hard
disk drives that are not yet configured as a RAID set. This configuration
stores the same data redundantly on multiple disks that appear as a single
disk on the operating system. Spanning does not deliver any advantage
over using separate disks independently and does not provide fault
tolerance or other RAID performance benefits.
If you want to boot the system from a hard disk drive included in a
created RAID set, copy first the RAID driver from the support CD to a
floppy disk before you install an operating system to the selected hard
disk drive. Refer to Chapter 6 for details.