xReferencesRefer to the following sources for additional information, and for product and software updates.1. ASUS Server Web-based Management (ASWM)
5-28 Chapter 5: BIOS setup5.7 Boot menuThe Boot menu items allow you to change the system boot options. Select an item then press <Enter> to di
ASUS TS500-E5 5-295.7.2 BootSettingsCongurationQuick Boot [Enabled]Enabling this item allows the BIOS to skip some power on self tests (POST) whil
5-30 Chapter 5: BIOS setupInterrupt 19 Capture [Enabled]When set to [Enabled], this function allows the option ROMs to trap Interrupt 19. Conguration
ASUS TS500-E5 5-31After you have set a supervisor password, the other items appear to allow you to change other security settings. User Access Level [
5-32 Chapter 5: BIOS setup5.8 Exit menuThe Exit menu items allow you to load the optimal or failsafe default values for the BIOS items, and save or d
This chapter provides instructions for setting up, creating and conguring RAID sets using the available utilities.Chapter 6RAIDconguration
6-2 Chapter 6: RAID conguration6.1 Setting up RAIDThe motherboard comes with the following RAID solutions:• LSI Software RAID Conguration Utility
ASUS TS500-E5 6-36.1.2 Installing hard disk drivesThe motherboard supports Serial ATA for RAID set conguration. For optimal performance, install ide
6-4 Chapter 6: RAID conguration3. The utility main window appears. Use the arrow keys to select an option from the Management Menu, then press <E
ASUS TS500-E5 6-56.2.1 Creating a RAID 0 or RAID 1 setThe LSI Software RAID Conguration Utility allows you to create a RAID 0 or RAID 1 set using tw
1-This chapter describes the general features of the chassis kit. It includes sections on front panel and rear panel specications.Chapter 1Product i
6-6 Chapter 6: RAID conguration4. Select all the drives required for the RAID set, then press <Enter>. The congurable array appears on screen
ASUS TS500-E5 6-75. Press <F10>, select the congurable array, then press <SpaceBar>. Press <F10> again, the logical drive informa
6-8 Chapter 6: RAID conguration6. Select RAID from the Logical Drive menu, then press <Enter>.7. Select the RAID level from the menu, then pr
ASUS TS500-E5 6-910. When nished setting the selected logical drive conguration, select Accept from the menu, then press <Enter>.11. Follow
6-10 Chapter 6: RAID congurationUsingNewCongurationWhen a RAID set is already existing, using the NewConguration command erases the existing RAI
ASUS TS500-E5 6-116.2.2 Creating a RAID 10 setYou can create a RAID 10 set using four identical hard disk drives.To create a RAID 10 set using the Ea
6-12 Chapter 6: RAID conguration4. Select all the drives required for the RAID 10 set, then press <Enter>. The congurable array appears on sc
ASUS TS500-E5 6-13 Press <F10> again, the logical drive information appears including a Logical Drive menu that allows you to change the logica
6-14 Chapter 6: RAID conguration10. When nished setting the selected logical drive conguration, select Accept from the menu, then press <Enter&
ASUS TS500-E5 6-156.2.3 AddingorviewingaRAIDcongurationYou can add a new RAID conguration or view an existing conguration using the View/Add
Chapter 1: Product introduction1-21.1 System package contents*ASUS System Web-based ManagementIf any of the above items is damaged or missing, conta
6-16 Chapter 6: RAID conguration4. Select all the drives required for the RAID set, then press <Enter>. The congurable array appears on scree
ASUS TS500-E5 6-178. Follow steps 8 to 12 of the CreatingaRAIDset:UsingEasyConguration section.9. When prompted, save the conguration, then
6-18 Chapter 6: RAID conguration6.2.4 Initializing the logical drivesAfter creating the RAID set(s), you must initialize the logical drives. You may
ASUS TS500-E5 6-193. When prompted, press the <SpaceBar> to select Yes from the Initialize? dialog box, then press <Enter>. You may also
6-20 Chapter 6: RAID conguration5. When initialization is completed, press <Esc>.UsingtheObjectscommandTo initialize the logical drives usi
ASUS TS500-E5 6-212. Select Virtual Drive from the Objects sub-menu, then press <Enter>.3. Select the logical drive to initialize from the Vir
6-22 Chapter 6: RAID conguration5. When prompted, press the <SpaceBar> to select Yes from the Initialize? dialog box, then press <Enter>
ASUS TS500-E5 6-236.2.5 Rebuilding failed drivesYou can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu.To
6-24 Chapter 6: RAID conguration3. After selecting the drive to rebuild, press <F10>. The indicator for the selected drive now shows RBLD.4.
ASUS TS500-E5 6-256.2.6 Checking the drives for data consistencyYou can check and verify the accuracy of data redundancy in the selected logical driv
ASUS TS500-E5 1-31.3 SystemspecicationsThe ASUS TS500-E5 is a 5U barebone server system featuring the ASUS DSAN-DX/TS500-E5 server board. The serv
6-26 Chapter 6: RAID conguration3. When prompted, use the arrow keys to select Yes from the Consistency Check dialog box, then press <Enter>.
ASUS TS500-E5 6-27UsingtheObjectscommandTo check data consistency using the Objects command:1. From the Management Menu, select Objects, then sele
6-28 Chapter 6: RAID conguration6.2.7 DeletingaRAIDcongurationTo delete a RAID conguration:1. From the Management Menu, select Congure > C
ASUS TS500-E5 6-296.2.8 Selecting the boot drive from a RAID setYou must have created a new RAID conguration before you can select the boot drive fr
6-30 Chapter 6: RAID conguration6.2.9 Enabling the WriteCacheYou may enable the RAID controller’s WriteCache option to improve the data transmission
ASUS TS500-E5 6-316.3 Intel® Matrix Storage Manager Option ROM UtilityThe Intel® Matrix Storage Manager Option ROM utility allows you to create RAID
6-32 Chapter 6: RAID conguration6.3.1 Creating a RAID 0 set (Stripe)To create a RAID 0 set:1. From the utility main menu, select 1. Create RAID Vol
ASUS TS500-E5 6-336. Use the up/down arrow key to select the stripe size for the RAID 0 array, then press <Enter>. The available stripe size va
6-34 Chapter 6: RAID conguration6.3.2 Creating a RAID 1 set (Mirror)To create a RAID 1 set:1. From the utility main menu, select 1. Create RAID Vol
ASUS TS500-E5 6-356.3.3 Creating a RAID 10 set (Stripe + Mirror)To create a RAID 10 set:1. From the utility main menu, select 1. Create RAID Volume,
Chapter 1: Product introduction1-4*Specicationsaresubjecttochangewithoutnotice.Model Name TS500-E5/PA4 TS500-E5/RX8HDD Bays I = internal A or
6-36 Chapter 6: RAID conguration6.3.4 Creating a RAID 5 set (Parity)To create a RAID 5 set:1. From the utility main menu, select 1. Create RAID Vol
ASUS TS500-E5 6-376.3.5 Deleting a RAID setTake caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RA
6-38 Chapter 6: RAID conguration6.3.7 Exiting the Intel® Matrix Storage ManagerTo exit the utility:1. From the utility main menu, select 4. Exit, t
Chapter 7Driver installationThis chapter provides instructions for installing the necessary drivers for different system components.
7-2 Chapter 7: Driver installation7.1 RAID driver installationAfter creating the RAID sets for your server system, you are now ready to install an op
ASUS TS500-E5 7-37. Locate the RAID driver and place a blank, high-density oppy disk to the oppy disk drive.8. Press <Enter>.9. Follow scre
7-4 Chapter 7: Driver installationTo create a RAID driver disk in Windows® Server environment:1. Restart the system from the hard disk drive, then pl
ASUS TS500-E5 7-57.1.2 Installing the RAID controller driverWindows® Server OSDuring Windows® Server OS installationTo install the RAID controller dr
7-6 Chapter 7: Driver installation4. Insert the RAID driver disk you created earlier to the oppy disk drive, then press <Enter>.5. Select the
ASUS TS500-E5 7-75. Right-click the RAID controller item, then select Properties.6. Click the Driver tab, then click the Update Driver button.7. Th
ASUS TS500-E5 1-51.4 Front panel featuresThe barebone server displays a simple yet stylish front panel with easily accessible features. The power and
7-8 Chapter 7: Driver installation2. At the boot:, type linux dd , then press <Enter>.4. Right-click the RAID controller driver item, then sel
ASUS TS500-E5 7-94. Select fd0 using the <Tab> key when asked to select the driver disk source. Press <Tab> to move the cursor to OK, the
7-10 Chapter 7: Driver installation6. Follow screen instructions to continue the OS installation.5. When prompted, insert the Red Hat® Enterprise RA
ASUS TS500-E5 7-11SuSE LinuxTo install the RAID controller driver when installing SuSE Linux OS:1. Boot the system from the SuSE Installation CD.2.
7-12 Chapter 7: Driver installation4. When prompted, insert the RAID driver disk to the oppy disk drive, then press <Enter>.5. When prompted,
ASUS TS500-E5 7-137.2 Intel® chipset device installationThis section provides instructions on how to install the Plug and Play components for the Int
7-14 Chapter 7: Driver installation4. The Intel(R) Chipset Device Software window appears. Click Next to start installation.5. Select Yes to accept
ASUS TS500-E5 7-156. Read the Readme File Information and press Next to continue the installation.7. After completing the installation, click Finish
7-16 Chapter 7: Driver installation7.3 LAN driver installationThis section provides instructions on how to install the Broadcom® Gigabit LAN controll
ASUS TS500-E5 7-174. Click Next when the InstallShield Wizard window appears.5. Toggle I accept the terms in the license agreement and click Next to
Chapter 1: Product introduction1-61.4.2 Eight Hot-Swap HDD Devices 4-bay HDD cage4-bay HDD cageThis server system provides 4-bay HDD Cage + 4 x Ho
7-18 Chapter 7: Driver installation6. Click Install to start the installation.7. Click Finish to exit the wizard when the installation is completed.
ASUS TS500-E5 7-197.4 VGA driver installationThis section provides instructions on how to install the XGI Volari Z9s Video Graphics Adapter (VGA) dri
7-20 Chapter 7: Driver installation5. The system will update the VGA driver.6. When the installation completes, click Finish to restart your compute
ASUS TS500-E5 7-217.5 Management applications and utilities installationThe support CD that came with the motherboard package contains the drivers,
7-22 Chapter 7: Driver installation7.5.3 Management Software menuThe Management Software menu displays the available network and server monitoring ap
ASUS TS500-E5 1-71.5 Rear panel featuresThe rear panel includes a slot for the motherboard rear I/O ports, expansion slots, a chassis lock and intrus
Chapter 1: Product introduction1-81.6 Internal featuresThe barebone server includes the basic components as shown.1. Power supply unit: PA4 model:
ASUS TS500-E5 1-91.7 LED information1.7.1 Front panel LEDsThe Power, HDD Access, LAN and Message LEDs are visible even if the system front bezel is
iiCopyright © 2008 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and software described in it, may be repro
Chapter 1: Product introduction1-101.7.2 Rear panel LEDsSPEED LEDACT/LINK LEDSPEED LEDACT/LINK LEDACT/LINK LED SPEED LEDStatus Description Status De
2-This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.Chapter 2Hardware setup
Chapter 2: Hardware setup2-22.1 Chassis cover2.1.1 Removing the side cover• Ensure that you unplug the power cord before removing the side cover.•
2-3ASUS TS500-E52.1.2 Reinstalling the side coverTo reinstall the side cover:1. Match and insert the lower sliding edge of the side cover to the cor
Chapter 2: Hardware setup2-42.2.1 Installing the CPUTo install a CPU:1. Locate the CPU socket on the motherboard.2.2 Central Processing Unit (CPU)
2-5ASUS TS500-E53. Lift the load lever in the direction of the arrow to a 135º angle.4. Lift the load plate with your thumb and forenger to a 100º
Chapter 2: Hardware setup2-6The CPU ts in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on th
2-7ASUS TS500-E52.2.2 Installing the CPU heatsink and fanTo install the CPU heatsink and fan:1. Place the CPU heatsink and fan on top of the install
Chapter 2: Hardware setup2-82.3 System memory2.3.1 OverviewThe motherboard comes with six (6) Double Data Rate 2 (DDR2) Dual Inline Memory Modules
2-9ASUS TS500-E5Rank populationDIMM installation reference tableDIMM_B1DIMM_A1DIMM_B2DIMM_A2DIMM_B3DIMM_A3MCHNo. of DIMMsSlot/s to use1 DIMM_B1 or DIM
iiiContentsContents ... iiiNotices ...
Chapter 2: Hardware setup2-102.3.3 Memory mirroring and sparing technologyThe Intel® 5100MCH chipset supports the memory sparing technology. Refer t
2-11ASUS TS500-E5Two DIMMs per channelThree DIMMs per channelChannel B Channel ADIMM_B1 (512MB*2 Ranks)DIMM_A1 (512MB*2 Ranks)Rank 0 (512 MB)Rank 1 (5
Chapter 2: Hardware setup2-122.3.4 Installing a DIMMMake sure to unplug the power supply before adding or removing DIMMs or other system components.
2-13ASUS TS500-E52.4 Front panel assemblyBefore you can install a 5.25-inch drive, you should rst remove the front panel assembly (front bezel and f
Chapter 2: Hardware setup2-142.5 5.25-inch or 3.5-inch drivesThe system comes with three 5.25-inch drive bays located on the upper front part of the
2-15ASUS TS500-E52.5.2 Installing a 3.5-inch drive1. Remove the metal bracket in front of the drive bay converter.2. Install the 3.5-inch disk driv
Chapter 2: Hardware setup2-162.6 SATA/SAS hard disk drivesThe optional two hard disk drive modules on the front panel, including externally removabl
2-17ASUS TS500-E53. Unscrew and remove the blank tray from the frame.4. Place a hard disk drive on the tray and secure it with four screws.To instal
Chapter 2: Hardware setup2-185. Insert the HDD-installed tray back into the bay.6. Carefully push the tray all the way to the depth of the bay.7.
2-19ASUS TS500-E5Removing and reinstalling the backplaneDO NOT remove the backplane unless necessary!1. Remove the hot-swap HDD module from the bay i
ivContents2.5 5.25-inch or 3.5-inch drives ... 2-142.5.1 Installing a 5.25-inch drive ...
Chapter 2: Hardware setup2-202.7 Expansion cardsThe system is designed with an expansion card lock on the rear panel for you to install or remove an
2-21ASUS TS500-E56. Restore the expansion card lock to its original position. A light click indicates that the card is locked in place.2.7.2 Install
Chapter 2: Hardware setup2-222.7.3 ConguringanexpansioncardAfter installing the expansion card, congure the it by adjusting the software settin
2-23ASUS TS500-E5DSAN-DX®24.5cm (9.6in)24.5cm (9.6in)DDR DIMM_A3 (64bit, 240-pin module)DDR DIMM_B3 (64bit, 240-pin module)DDR DIMM_A2 (64bit, 240-pin
Chapter 2: Hardware setup2-242.8.2 SATA/SAS backplane connections A SATA/SAS backplane comes pre-installed in the TS500-E5. The SATA/SAS backplane h
2-25ASUS TS500-E5Back sideThe back side of the SATA/SAS backplane faces the rear panel when installed. This side includes the power connectors and SAT
Chapter 2: Hardware setup2-262. Shift the two hooked tabs upward and downward.2.9.1 System fanTo remove the system fan:1. Unplug the system fan ca
2-27ASUS TS500-E5To reinstall the system fan:1. Shift the two hooked tabs upward and downward, and then install the system fan. A light click indicat
Chapter 2: Hardware setup2-282.9.2 Chassis footpadsThe barebone server system is shipped with four footpads attached to the bottom of the chassis fo
2-29ASUS TS500-E52.9.3 Power supply unitThe system is compatible with both EPS 12 V 670 W single power supply and 650 W redundant power supply. Purch
vContents5.2.4 Menu items ... 5-95.2.5 Sub-menu items ...
Chapter 2: Hardware setup2-303. Insert the redundant power supply into the power supply bay.4. Make the redundant power supply cage sit on the shel
2-This chapter describes how to install the optional components and devices into the barebone server.Chapter 3Installation options
Chapter 3: Installation options3-2Removing the top coverUnscrew and slide the top cover toward the rear panel, and then lift it up from the chassis.3
3-3ASUS TS500-E53.3 Attaching the rails to the rackTo attach the rails to the rack:1. Select one unit of space (1U) on the rack where you wish to in
Chapter 3: Installation options3-43.4 Mounting the server to the rackTo mount the server to the rack:1. Align the server rails with the rack rails.
Chapter 4Motherboard infoThis chapter includes the motherboard layout, and brief descriptions of the jumpers and internal connectors.
Chapter 4: Motherboard information4-24.1 Motherboard layoutDSAN-DX/TS500-E5®24.5cm (9.6in)24.5cm (9.6in)DDR DIMM_A3 (64bit, 240-pin module)DDR DIMM_B
ASUS TS500-E5 4-3Layout contentsJumpers Page1. Clear RTC RAM (CLRTC1)4-42. VGA controller setting (3-pin VGA_SW1)4-53. LAN controller setting (3-pi
Chapter 4: Motherboard information4-44.2 Jumpers1. Clear RTC RAM (CLRTC1)This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You
ASUS TS500-E5 4-52. VGA controller setting (3-pin VGA_SW1)This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to
viContents6.1.3 Setting the RAID item in BIOS ... 6-36.1.4 RAID conguration utilities ...
Chapter 4: Motherboard information4-64. CPU Fan control setting (3-pin CPUFAN_SEL1)This jumper allows you to switch for fan pin selection. The CPUFAN
ASUS TS500-E5 4-76. IDE setting (3-pin IDE_SW1)This jumper allows you to enable or disable the onboard IDE connector. Set to pins 1–2 to activate the
Chapter 4: Motherboard information4-89. iBTN RAID setting (3-pin IBTN_SEL1)This jumper allows you to select the RAID conguration utility to use when
ASUS TS500-E5 4-94.3 Internal connectors1. Floppy disk drive connector (34-1 pin FLOPPY1)This connector is for the provided oppy disk drive (FDD) s
Chapter 4: Motherboard information4-103. IDE connector (40-1 pin PRI_EIDE1)This connector is for an Ultra DMA 100/66 signal cable. The Ultra DMA 100
ASUS TS500-E5 4-11®DSAN-DX/TS500-E5DSAN-DX/TS500-E5 Storage card activity LED connectorNCADD_IN_CARD-ADD_IN_CARD-NCHDLED4. SAS connectors [red] (7-pi
Chapter 4: Motherboard information4-126. Serial General Purpose Input/Output connector (6-1 pin SGPIO1)This connector is used for the SGPIO periphera
ASUS TS500-E5 4-138. USB connectors (10-1 pin USB34, USB56)These connectors is for USB 2.0 ports. Connect the USB module cable to the connectors, the
Chapter 4: Motherboard information4-1410. Serial port connector (10-1 pin COM2)This connector is for a serial (COM) port. Connect the serial port mod
ASUS TS500-E5 4-1512. SSI power connectors (24-pin ATXPWR1, 8-pin ATX12V1)These connectors are for SSI power supply plugs. The power supply plugs are
viiNoticesFederal Communications Commission StatementThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two con
Chapter 4: Motherboard information4-1613. System panel connector [white] (20-pin PANEL1)This connector supports several chassis-mounted functions.1.
ASUS TS500-E5 4-1714. Auxiliary panel connector [black] (20-pin AUX_PANEL1)This connector is for additional front panel features including front pane
Chapter 4: Motherboard information4-18
Chapter 5BIOS setupThis chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters ar
5-2 Chapter 5: BIOS setup5.1 Managing and updating your BIOSThe following utilities allow you to manage and update the motherboard Basic Input/Output
ASUS TS500-E5 5-35.1.2 AFUDOS utilityThe AFUDOS utility allows you to update the BIOS le in DOS environment using a bootable oppy disk with the upd
5-4 Chapter 5: BIOS setupA:\>afudos /iTS500-E5.ROMAMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB))Copyright (C) 2002 American Meg
ASUS TS500-E5 5-55. The utility returns to the DOS prompt after the BIOS update process is completed. Reboot the system from the hard disk drive.A:\&
5-6 Chapter 5: BIOS setup5.1.3 ASUS CrashFree BIOS 3 utilityThe ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS l
ASUS TS500-E5 5-75.2 BIOS setup programThis motherboard supports a programmable Low-Pin Count (LPC) chip that you can update using the provided utili
viiiSafety informationElectrical Safety• Before installing or removing signal cables, ensure that the power cables for the system unit and all attach
5-8 Chapter 5: BIOS setupv02.61 (C)Copyright 1985-2008, American Megatrends, Inc.BIOS SETUP UTILITY Main Advanced Server Power Boot Exi
ASUS TS500-E5 5-95.2.4 Menu itemsThe highlighted item on the menu bar displays the specic items for that menu. For example, selecting Main shows th
5-10 Chapter 5: BIOS setup5.3 Main menuWhen you enter the BIOS Setup program, the Main menu screen appears, giving you an overview of the basic syste
ASUS TS500-E5 5-115.3.4 SATA1–6; PATA Master/SlaveThe BIOS automatically detects the connected IDE devices. There is a separate sub-menu for each IDE
5-12 Chapter 5: BIOS setupPIO Mode [Auto]Allows you to select the data transfer mode. Conguration options: [Auto] [0] [1] [2] [3] [4]DMA Mode [Auto]S
ASUS TS500-E5 5-13v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.BIOS SETUP UTILITY Main IDE Conguration SATA#1 Conguration [Enhanced]
5-14 Chapter 5: BIOS setup5.3.6 System InformationThis menu gives you an overview of the general system specications. The BIOS automatically detects
ASUS TS500-E5 5-155.4 Advanced menuThe Advanced menu items allow you to change the settings for the CPU and other system devices.Take caution when ch
5-16 Chapter 5: BIOS setupUSB Functions [Enabled]Allows you to enable the USB host controller. Conguration options: [Disabled] [Enabled]The following
ASUS TS500-E5 5-17v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.BIOS SETUP UTILITY Advanced Congure advanced CPU settingsModule Vers
ixAbout this guideAudienceThis user guide is intended for system integrators, and experienced users with at least basic knowledge of conguring a serv
5-18 Chapter 5: BIOS setupMax CPUID Value Limit [Disabled]Setting this item to [Enabled] allows legacy operating systems to boot even without support
ASUS TS500-E5 5-19v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.BIOS SETUP UTILITY Advanced Advanced Chipset Settings WARNING: Settin
5-20 Chapter 5: BIOS setupPatrol Scrubbing [Enabled]Enables or disables the Patrol Scrubbing. Conguration options: [Disabled] [Enabled]Demand Scrubbi
ASUS TS500-E5 5-21v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.BIOS SETUP UTILITY Advanced Congure Win627EHF Super IO ChipsetSerial
5-22 Chapter 5: BIOS setup5.4.5 PCIPnPThe PCIPnP menu items allow you to change the advanced settings for PCI/PnP devices. The menu includes setting
ASUS TS500-E5 5-23Remote Access [Enabled]Enables or disables the remote access feature. Conguration options: [Disabled] [Enabled]The following items
5-24 Chapter 5: BIOS setupSerial port number [COM2]Selects the serial port for console redirection. Conguration options: [COM1] [COM2]Base Address. I
ASUS TS500-E5 5-255.6 Power menuThe Power menu items allow you to change the settings for the Advanced Power Management (APM). Select an item then pr
5-26 Chapter 5: BIOS setupRestore on AC Power Loss [Last State]When set to [Power Off], the system goes into off state after an AC power loss. When se
ASUS TS500-E5 5-275.6.4 Hardware Monitorv02.61 (C)Copyright 1985-2008, American Megatrends, Inc.BIOS SETUP UTILITY Power