GESTEK
Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Page 19 of 27
Listed Lab. of Commerce, FCC, VCCI. NVLAP Lab Code:200085-0
5.7 RADIATED EMISSIONS MEASUREMENT RESULTS
Date of Test December 18, 2007 Temperature 26 deg/C
EUT Server Humidity 60 %RH
Working Cond. Mode 5 Display Pattern H Pattern
Antenna distance 10m at Horizontal Frequency Range 30-1000MHz
Test Power Supply AC 100V/50Hz
No.
Frequency
MHz
Reading Level
dBµV
Factor
dB
Measurement
dBµV/m
Limit
dBµV/m
Over Limit
dB
Detector
1 129.6269 33.60 -12.47 21.13 40.00 -18.87 QP
2 140.4372 31.65 -12.78 18.87 40.00 -21.13 QP
3 160.9100 32.38 -13.87 18.51 40.00 -21.49 QP
4 203.3982 33.21 -13.57 19.64 40.00 -20.36 QP
5 240.0325 41.00 -10.74 30.26 47.00 -16.74 QP
6 384.0017 41.56 -6.52 35.04 47.00 -11.96 QP
7 398.2269 33.41 -6.14 27.27 47.00 -19.73 QP
8 480.0437 37.68 -4.74 32.94 47.00 -14.06 QP
9 600.1261 33.60 -2.58 31.02 47.00 -15.98 QP
10
★
674.9944
43.90 -1.49 42.41 47.00 -4.59 QP
11 799.7189 31.60 0.18 31.78 47.00 -15.22 QP
12 965.0271 37.20 2.56 39.76 47.00 -7.24 QP
Remarks:
1. All Readings below 1GHz are Quasi-Peak.
2. Measurement = Reading + Factor (Could have
±
0.01 tolerance due to computer automatically round off calculation).
3. Over Limit (Margin Value)=Measurement level-Limit value.
4. Factor = antenna factor + cable loss – amplifier gain.
5. “
★
” means that this data is the worse case measurement level.
6. The measurement uncertainty is 5.1 dB.
Remark: 1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “Margin” refers to the data under 6dB.