Asus AP1600R User's Guide

Browse online or download User's Guide for Servers Asus AP1600R. Asus AP1600R User guide [en] User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - User Guide

Dual Intel® Xeon™ 533MHz FSBAP1600RUser Guide1U Rackmount Server

Page 2 - Disclaimer/Copyrights

10Introduction: About this guideAudienceContentsThis guide contains the following parts:1. Introduction: About this guideThis part introduces the cont

Page 3

ASUS AP1600R 1U Rackmount Server11ConventionsSymbolsTo make sure that you perform certain tasks properly, take note of the followingsymbols used throu

Page 4

12Introduction: About this guideSystem Package ContentsThe following checklist enumerates the components included in the systempackage.Standard items1

Page 5 - ASUS Contact Information

13ASUS AP1600R 1U Rackmount ServerThis chapter describes the general featuresof the AP1600R server. It includes sectionson front panel, rear panel, an

Page 6

14Chapter 1: System Overview1.1 System FeaturesThe ASUS AP1600R is a stylish 1U barebone server featuring the ASUSPR-DLSR533 motherboard. The server

Page 7 - Safety Precautions

ASUS AP1600R 1U Rackmount Server151.2 Front Panel FeaturesThe server front panel allows easy access to the hard disk drives. The powerand reset button

Page 8

16Chapter 1: System Overview1.4 System LED indicatorsFront panel (left side)Front panel (right side)Rear panelPower LEDLocation LEDMessage LEDLocatio

Page 9 - About this guide

ASUS AP1600R 1U Rackmount Server17HDD power LEDsThere are four HDD power LEDs, one for each SCSI HDD.• The LED lights up steady GREEN when an HDD is i

Page 10 - Contents

18Chapter 1: System Overview1.5 Internal FeaturesThe standard components inside the AP1600R server include themotherboard, backplane, bridge board, f

Page 11 - References

19ASUS AP1600R-S5 1U Rackmount ServerThis chapter describes the hardware setupprocedures that you have to perform wheninstalling system components.Cha

Page 12 - System Package Contents

2Disclaimer/CopyrightsNo part of this manual, including the products and software described in it, may be reproduced,transmitted, transcribed, stored

Page 13 - System Overview

20Chapter 2: Hardware Setup2.1 Removing and installing the chassis coverRemoving the cover1. To release the cover, push thetwo latches outward, then

Page 14 - 1.1 System Features

ASUS AP1600R-S5 1U Rackmount Server21Placement DirectionWhen installing the motherboard,make sure that you place it into thechassis correctly. The edg

Page 15 - 1.2 Front Panel Features

22Chapter 2: Hardware Setup2.3 Installing and removing the airflow guideTo detach the airflow guide, use a Phillips screwdriver to remove the twoscre

Page 16 - 1.4 System LED indicators

ASUS AP1600R 1U Rackmount Server232.4 Installing CPU and heatsinkThe 604-pin Zero Insertion Force (ZIF) sockets on the PR-DLSR533motherboard support d

Page 17

24Chapter 2: Hardware Setup2. Position the CPU above thesocket as shown.3. Carefully insert the CPU intothe socket until it fits in place.4. When the

Page 18 - 1.5 Internal Features

ASUS AP1600R 1U Rackmount Server25Install the Heatsink1. Carefully place the heatsink ontop of the installed CPU. Theheatsink fits in only oneorientat

Page 19 - Hardware Setup

26Chapter 2: Hardware Setup2.5 Installing system memoryThe motherboard has six Dual InlineMemory Module (DIMM) socketsthat support up to 12GB systemm

Page 20 - Installing the cover

ASUS AP1600R 1U Rackmount Server272.6 Installing the backplane and bridge boardsBridge board (BRIDGE-AR12)The bridge board links several functions and

Page 21 - 2.2 Motherboard Placement

28Chapter 2: Hardware SetupWhen installed, the SCSI bridge board appears as shown below. Connectthe SCSI cable to the connectors on the bridge board

Page 22 - Airflow guide

ASUS AP1600R 1U Rackmount Server29Backplane boardThe backplane board includes the four hot-swappable connectors for theSCSI drives accessible from the

Page 23 - Xeon Processor

3ContentsDisclaimer/Copyrights ... 2ASUS Contact Information ...

Page 24 - Install the CPU

30Chapter 2: Hardware Setup2.7 Installing a hard disk drive1. Push the thumb pad all theway to the right to release theHDD tray.2. Pull out the tray

Page 25 - Install the Heatsink

ASUS AP1600R 1U Rackmount Server315. Push the tray all the way to thedepth of the bay until it fits.6. Push the tray handle back inplace.Make sure tha

Page 26 - 2.5 Installing system memory

32Chapter 2: Hardware Setup2.8 Installing a PCI card1. The PCI riser card and cardbracket assembly comespre-installed in the chassis.Pull up the meta

Page 27 - Bridge board (BRIDGE/S-AR12)

ASUS AP1600R 1U Rackmount Server334. When the riser card assemblyis in place, push down the cardholder to secure the end of theextended PCI card.The p

Page 28 - Chapter 2: Hardware Setup

34Chapter 2: Hardware Setup2.9 Installing the front bezel and rack ears1. Secure a metal handle to oneend of the front bezel using twosmall screws th

Page 29 - Backplane board

ASUS AP1600R 1U Rackmount Server352.10 Installing CD-ROM and floppy drives1. When shipped, the rails of thecombo box are attached to thesides as shown

Page 30

36Chapter 2: Hardware Setup5. Follow steps 1 to 4 to install theother rail.6. Insert the rails to the holes onthe front panel and match the68-pin con

Page 31

37ASUS AP1600R 1U Rackmount ServerThis chapter describes the optional hardwareprocedures that you may have to do whenconfiguring the system.Chapter 3

Page 32 - 2.8 Installing a PCI card

38Chapter 3: Powering Up3.1 Cooling SystemThere are ten (10) 40 x 40 x 28mm fans in the chassis to maintain the optimaltemperatures of the CPU, PCI c

Page 33

ASUS AP1600R 1U Rackmount Server39Fan cable connectionsThe fan module numbered 5-6-7-8 (see location in the abovepicture) connects to SYSFAN1 connecto

Page 34 - Mounting ear

4Contents2.6 Installing the backplane and bridge boards ... 27Bridge board (BRIDGE-AR12) ...

Page 35 - Loosen this screw

40Chapter 3: Powering UpRemoving the fansRemove the fans only when they get damaged and need to be replaced.System fan modulesTo remove a system fan

Page 36

ASUS AP1600R 1U Rackmount Server413.2 Power connectionsThe server provides a “cable-less” solution for easy assembly andmaintenance. Most of the cable

Page 37 - Hardware Options

42Chapter 3: Powering Up3.3 Removing the power supplyFollow these steps in case you need to remove the power supply in thefuture.2. Remove the two sc

Page 38 - 3.1 Cooling System

43ASUS AP1600R-S5 1U Rackmount ServerThis appendix gives information on the 350Wswitching power supply that comes with theAP1600R-S5 server.Appendix A

Page 39 - Fan cable connections

44Appendix A: Power SupplyA.1 General DescriptionThe server comes with an SSI-type 350W ATX power supply with universalAC input that includes PFC an

Page 40 - Removing the fans

ASUS AP1600R-S5 1U Rackmount Server45Input CharacteristicsA.2 SpecificationsOutput CharacteristicsOver-Voltage Protection (OVP)Input Voltage Range Min

Page 41 - 3.2 Power connections

46Appendix A: Power Supply

Page 42 - 3.3 Removing the power supply

47ASUS AP1600R-S5 1U Rackmount ServerThis appendix lists the common problems thatyou may encounter while using theAP1600R-S5 server. It lists the poss

Page 43 - Power Supply

48Appendix B: TroubleshootingB.1 Simple FixesThe power LED on the serverand/or the monitor do not lightup1. Check the power cableconnection on the sy

Page 44 - A.1 General Description

ASUS AP1600R-S5 1U Rackmount Server49The system does not performpower-on self tests (POST) afterit was turned on1. Check the memory modulesand make su

Page 45 - A.2 Specifications

5ASUS Contact InformationASUSTeK COMPUTER INC. (Asia-Pacific)Address: 150 Li-Te Road, Peitou, Taipei, Taiwan 112General Tel: +886-2-2894-3447General F

Page 46 - Appendix A: Power Supply

50Appendix B: Troubleshooting

Page 47 - Troubleshooting

6NoticesFederal Communications Commission StatementThis device complies with FCC Rules Part 15. Operation is subject to the followingtwo conditions:•

Page 48 - B.1 Simple Fixes

7Safety PrecautionsElectrical SafetyOperation SafetyIMPORTANT•Before installing or removing signal cables, ensure that the powercables for the system

Page 50 - Appendix B: Troubleshooting

9ASUS AP1600R 1U Rackmount ServerIntroductionAbout this guide“About This Guide” introduces the contentsof this document. This part includes the target

Comments to this Manuals

No comments