Asus ASMB3 User Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
2-16 Chapter 2: Installation
System Event Log (list mode)
Press <Enter> to open the System Event Log in list mode.
F1 Help ↑↓ Select Item -/+ Change Values F9 Setup Defaults
ESC: Exit →← Select Menu Enter Select Sub-menu F10 Save and Exit
System Event Log (list mode)
Event ID Sensor Name Sensor Type Date/Time Stamp
------------------------------------------------------------------------------
001 CPU2temperature1 Temp 04/17/2006 16:10:44
Upper Non-critical Going High, Assertion
002 CPU2temperature1 Temp 04/17/2006 16:10:44
Upper Critical Going High, Assertion
003 CPU2temperature2 Temp 04/17/2006 16:10:44
Upper Non-critical Going High, Assertion
004 CPU2temperature2 Temp 04/17/2006 16:10:44
Upper Critical Going High, Assertion
005 DIMM_01 AMB temp Temp 04/17/2006 16:10:44
Lower Non-critical Going Low, Assertion
006 DIMM_01 AMB temp Temp 04/17/2006 16:10:45
Upper Critical Going Low, Assertion
PhoenixBIOS Setup Utility
Main Advanced Server Security Boot Exit
F1 Help ↑↓ Select Item -/+ Change Values F9 Setup Defaults
ESC: Exit →← Select Menu Enter Select Sub-menu F10 Save and Exit
[0001 CPU2temperature1 Temp 04/17/2006 16:10:44 ]
SEL Entry Number = 1
SEL Record ID = 0001
SEL Record Type = 02-System Event Record
Timestamp = 04/17/2006 16:10:44
Generator Id = 20 00
SEL Message Rev = 04
Sensor Type = 01 - Temperature
Sensor Number = 32 - CPU2temperature1
SEL Event Type = 01 - Threshold
Event Description = Upper Non-critical Going High, Assertion
SEL Event Data = 57 80 50
PhoenixBIOS Setup Utility
Main Advanced Server Security Boot Exit
Choose an event ID, then press <Enter> to view the details.
IP Address
Allows you to provide information to set the BMC IP address.