2-30 Chapter 2: BIOS setup
2.5.5 APM Conguration
APM Conguration
Restore on AC Power Loss [Disabled]
Power On By PS/2 Keyboard [Disabled]
Power On By PS/2 Mouse [Disabled]
Power On By External Modems [Disabled]
Power On By PCI/PCIe Devices [Disabled]
RTC Resume [Disabled]
Restore on AC Power Loss [Disabled]
When set to [Power Off], the system goes into off state after an AC power loss.
When set to [Power On], the system goes on after an AC power loss. When set to
[Last State], the system goes into either off or on state, whatever the system state
was before the AC power loss.

Power On By PS/2 Keyboard [Disabled]

feature requires an ATX power supply that provides at least 1A on the +5VSB lead.

Power On By PS/2 Mouse [Disabled]
When set to [Enabled], this parameter allows you to use the PS/2 mouse to turn on
the system. This feature requires an ATX power supply that provides at least 1A on

Power On By External Modems [Disabled]
This allows either settings of [Enabled] or [Disabled] for powering up the computer
when the external modem receives a call while the computer is in Soft-off mode.

The computer cannot receive or transmit data until the computer and

try. Turning an external modem off and then back on while the computer is off

Power On By PCI/PCIe Devices [Disabled]
When set to [Enabled], this parameter allows you to turn on the system through a
PCI LAN or modem card. This feature requires an ATX power supply that provides
at least 1A on the +5VSB lead.

Options
Disabled
Power On
Power Off
Last State