Asus PIKE 1078 Specifications Page 1

Browse online or download Specifications for Servers Asus PIKE 1078. Asus PIKE 1078 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - SAS RAID card

PIKE 1078LSISAS1078 SAS RAID card

Page 2 - June 2008

1-4 Chapter 1: Product introduction1.5 Card installationFollow the below instructions to install the RAID card on your motherboard.Please do remember

Page 3 - Contents

ASUS PIKE 1078 1-55. Connect the SAS hard disk drives to the SAS connectors on the motherboard.4. Secure the heatsink to the nearest screw hole on t

Page 4 - About this guide

1-6 Chapter 1: Product introductionFor 1U serverYou have to remove the outer heatsink of ASUS PIKE 1078 SAS RAID card to install the card in a 1U serv

Page 5 - Typography

ASUS PIKE 1078 1-74. Align the golden ngers of the RAID card with the PIKE RAID card slot.5. Insert the RAID card into the PIKE RAID card slot. Mak

Page 6

1-8 Chapter 1: Product introduction

Page 7 - Chapter 1: Product

2Chapter 2: RAID congurationThis chapter provides instructions on setting up, creating, and conguring RAID sets using the available utilities.

Page 8 - 1.2 Package contents

2-2 Chapter 2: RAID conguration2.1 Setting up RAIDThe RAID card supports RAID 0, RAID 1, RAID 10, RAID 5, RAID 50, RAID 6, and RAID 60 set(s).2.1.1

Page 9 - 1.4 System requirements

ASUS PIKE 1078 2-3If you want to boot the system from a hard disk drive included in a created RAID set, copy rst the RAID driver from the support CD

Page 10 - 1.5 Card installation

2-4 Chapter 2: RAID conguration2.2 LSI WebBIOS Conguration UtilityThe LSI WebBIOS Conguration Utility (CU) is an integrated RAID solution that all

Page 11 - ASUS PIKE 1078 1-5

ASUS PIKE 1078 2-52.2.2 WebBIOS CU main screen optionsThis is the Logical View screen, which displays in the lower right panel all virtual disks (vir

Page 12 - For 1U server

iiE3735First Edition V1 June 2008Copyright © 2008 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and softwar

Page 13 - ASUS PIKE 1078 1-7

2-6 Chapter 2: RAID congurationHere is a description of the options listed on the left of the main WebBIOS CU screen:• Adapter Properties: Select th

Page 14

ASUS PIKE 1078 2-72.2.3 Creating a Storage CongurationThis section explains how to use the WebBIOS CU Conguration Wizard to congure RAID arrays an

Page 15 - Chapter 2: RAID

2-8 Chapter 2: RAID congurationUsing Auto CongurationFollow these instructions to create a conguration with auto conguration, either with or witho

Page 16 - 2.1 Setting up RAID

ASUS PIKE 1078 2-93. When you have nished selecting physical disks for the disk groups, click Next. The span denition screen appears Select one of

Page 17 - ASUS PIKE 1078 2-3

2-10 Chapter 2: RAID conguration• Write Policy: Specify the write policy for this virtual drive: ◊ WBack: In Writeback mode the controller sends a

Page 18

ASUS PIKE 1078 2-118. Check the information in the conguration preview.9. If the virtual disk conguration is acceptable, click Accept to save the

Page 19 - WebBIOS CU Toolbar Icons

2-12 Chapter 2: RAID conguration3. When you have nished selecting physical disks for the disk groups, click Next. The span denition screen appear

Page 20

ASUS PIKE 1078 2-13 ◊ WBack: In Writeback mode the controller sends a data transfer completion signal to the host when the controller cache has recei

Page 21 - ASUS PIKE 1078 2-7

2-14 Chapter 2: RAID conguration7. Click Next when you are nished dening virtual disks. The conguration preview screen appears, as shown in the r

Page 22 - Using Auto Conguration

ASUS PIKE 1078 2-155. Change the virtual disk options from the defaults listed on the screen as needed. Here are brief explanations of the virtual d

Page 23 - ASUS PIKE 1078 2-9

iiiContentsContents ... iiiAbout this guide ...

Page 24

2-16 Chapter 2: RAID conguration ◊ WBack: In Writeback mode the controller sends a data transfer completion signal to the host when the controller c

Page 25 - ASUS PIKE 1078 2-11

ASUS PIKE 1078 2-178. Check the information in the conguration preview.9. If the virtual disk conguration is acceptable, click Accept to save the

Page 26

2-18 Chapter 2: RAID conguration2. Click Accept DG to move the drives to a proposed disk group conguration in the Disk Groups window on the right,

Page 27 - ASUS PIKE 1078 2-13

ASUS PIKE 1078 2-19 ◊ Ahead: This enables read ahead capability, which allows the controller to read sequentially ahead of requested data and to stor

Page 28

2-20 Chapter 2: RAID conguration• Select Size: Specify the size of the virtual disk in megabytes. Normally, this would be the full size for RAID 6 s

Page 29 - ASUS PIKE 1078 2-15

ASUS PIKE 1078 2-212. Click Accept DG to move the drives to a proposed two-drive disk group conguration in the Disk Groups window on the right. If

Page 30

2-22 Chapter 2: RAID conguration• RAID Level: The drop-down menu lists the possible RAID levels for the virtual disk. Select RAID 10.• Strip Size:

Page 31 - ASUS PIKE 1078 2-17

ASUS PIKE 1078 2-23 ◊ Direct: In Direct I/O mode, reads are not buffered in cache memory. Data is transferred to the cache and the host concurrently.

Page 32

2-24 Chapter 2: RAID congurationUsing Custom Conguration: RAID 50RAID 50 provides the features of both RAID 0 and RAID 5. RAID 50 uses both distribu

Page 33 - ASUS PIKE 1078 2-19

ASUS PIKE 1078 2-25 You use this screen to select the RAID level, strip size, read policy, and other attributes for the new virtual disk(s). 7. Hold

Page 34

ivAbout this guideThis user guide contains the information you need when installing and conguring the server management board.How this guide is organ

Page 35

2-26 Chapter 2: RAID conguration ◊ Wrthru for BAD BBU: Select WBack for Write Policy and unselect this item if you want the controller to use Writeb

Page 36

ASUS PIKE 1078 2-27Using Custom Conguration: RAID 60RAID 60 provides the features of both RAID 0 and RAID 6, and includes both parity and disk stripi

Page 37 - ASUS PIKE 1078 2-23

2-28 Chapter 2: RAID conguration5. When you have nished selecting physical disks for the disk groups, click Next. The span denition screen appear

Page 38

ASUS PIKE 1078 2-29 ◊ Adaptive: When Adaptive read ahead is selected, the controller begins using read ahead if the two most recent disk accesses occ

Page 39 - ASUS PIKE 1078 2-25

2-30 Chapter 2: RAID conguration9. Click Accept to accept the changes to the virtual disk denition, or click Back to return to the previous setting

Page 40

ASUS PIKE 1078 2-312.2.4 Viewing and Changing Device PropertiesThis section explains how you can use the WebBIOS CU to view and change the properties

Page 41 - ASUS PIKE 1078 2-27

2-32 Chapter 2: RAID congurationAdapter Properties Menu OptionsOption DescriptionBattery Backup This entry indicates whether the selected controller

Page 42

ASUS PIKE 1078 2-33Adapter Properties Menu Options (Cont.)Option DescriptionPDF Interval This option determines how frequently the controller polls fo

Page 43 - ASUS PIKE 1078 2-29

2-34 Chapter 2: RAID congurationViewing and Changing Virtual Disk PropertiesAccess the Virtual Disk screen by selecting a virtual disk (virtual disk)

Page 44

ASUS PIKE 1078 2-35• Select CC to run a consistency check on this virtual disk. In the right panel of the Virtual Disk screen you can change the vir

Page 45 - ASUS PIKE 1078 2-31

vTypographyBold text Indicates a menu or an item to select.Italics Used to emphasize a word or a phrase.<Key> Keys enclosed in the less-th

Page 46

2-36 Chapter 2: RAID conguration2.2.5 Viewing System Event InformationThe SAS controller rmware monitors the activity and performance of all storag

Page 47

ASUS PIKE 1078 2-372.2.6 Managing CongurationsThis section includes information about maintaining and managing storage congurations.Running a Consi

Page 48 - Slow Init

2-38 Chapter 2: RAID congurationThe WebBIOS CU allows you to import the foreign conguration to the RAID controller, or to clear the conguration so

Page 49

ASUS PIKE 1078 2-39Foreign Configurations in Cable Pull and Disk Removal ScenariosIf one or more physical disks are removed from a conguration, by a

Page 50

2-40 Chapter 2: RAID congurationMigrating the RAID Level of a Virtual DiskAs the amount of data and the number of disk drives in your system increase

Page 51 - 2.2.6 Managing Congurations

ASUS PIKE 1078 2-415. When you have made your selections, click Go at the bottom of the right panel.6. When the message appears, conrm that you wan

Page 52

2-42 Chapter 2: RAID conguration2.3 MegaRAID Storage ManagerMegaRAID Storage Manager software enables you to congure, monitor, and maintain storage

Page 53

ASUS PIKE 1078 2-434. Enter your user name and organization name. In the bottom part of the screen, select an installation option:– If you select Al

Page 54

2-44 Chapter 2: RAID conguration7. Select one of the Setup options. The options are fully explained in the screen text.– Normally, you would select

Page 55 - ASUS PIKE 1078 2-41

ASUS PIKE 1078 2-4510. Click Next to proceed.11. Click Install to install the program.12. When the nal Conguration Wizard screen appears, click F

Page 56 - 2.3 MegaRAID Storage Manager

viPIKE 1078 specications summary* Install the i-Button for PIKE 1078 to work properly.** The exact OS support would base on the OS support list of th

Page 57 - ASUS PIKE 1078 2-43

2-46 Chapter 2: RAID conguration2.3.3 Installing MegaRAID Storage Manager Sofware for LinuxFollow these steps if you need to install MegaRAID Sto

Page 58

ASUS PIKE 1078 2-472.3.4 Linux Error MessagesThe following messages may appear while you are installing MegaRAID Storage Manager software on a Linux

Page 59 - ASUS PIKE 1078 2-45

2-48 Chapter 2: RAID conguration2.3.5 Starting MegaRAID Storage Manager SoftwareFollow these steps to start MegaRAID Storage Manager software and vi

Page 60

ASUS PIKE 1078 2-49To access servers on a different subnet, type in the box at the bottom of the screen the IP address of a server in the desired subn

Page 61 - 2.3.4 Linux Error Messages

2-50 Chapter 2: RAID conguration2.3.6 MegaRAID Storage Manager WindowThis section describes the MegaRAID Storage Manager window, which is shown in t

Page 62

ASUS PIKE 1078 2-51• Array • Virtual disk • Physical drive • Enclosure • Battery backup unit (BBU) A red circle to the right of an icon indicates

Page 63

2-52 Chapter 2: RAID conguration• The Graphical View tab can be selected in the right panel if a physical drive, virtual disk, or disk enclosure is

Page 64 - Physical/Logical View Panel

ASUS PIKE 1078 2-53Operations MenuThe Operations menu is available when a controller, physical drive, or virtual disk is selected in the MegaRAID Stor

Page 65 - ASUS PIKE 1078 2-51

2-54 Chapter 2: RAID conguration

Page 66 - Menu Bar

3Chapter 3: Driver installationThis chapter provides instructions for installing the RAID drivers on different operating systems.

Page 67 - Help Menu

1Chapter 1: Product introductionThis chapter offers the PIKE 1078 SAS RAID card features and the new technologies it supports.

Page 68

3-2 Chapter 3: Driver installation3.1 RAID driver installationAfter creating the RAID sets for your server system, you are now ready to install an op

Page 69 - Chapter 3: Driver

ASUS PIKE 1078 3-38. Place a blank, high-density oppy disk to the oppy disk drive.9. Press <Enter>.10. Follow screen instructions to create

Page 70 - 3.1 RAID driver installation

3-4 Chapter 3: Driver installation3.1.2 Windows® OSDuring Windows® OS installationTo install the RAID card driver when installing Windows® OS:1. Boo

Page 71 - 9. Press <Enter>

ASUS PIKE 1078 3-54. Insert the RAID driver disk you created earlier to the oppy disk drive, then press <Enter>.Windows SetupENTER=Continue

Page 72 - 3.1.2 Windows

3-6 Chapter 3: Driver installationAfter Windows® OS installationTo update the RAID card driver after installing Windows® OS:1. Right-click the My Com

Page 73

ASUS PIKE 1078 3-75. Toggle Install from a list or specic location (Advanced), then click Next to continue.6. Toggle Don’t search. I will choose th

Page 74 - OS installation

3-8 Chapter 3: Driver installation9. Select from the drop-down menu and locate the driver.10. Click Next to start updating the driver.11. After com

Page 75 - ASUS PIKE 1078 3-7

ASUS PIKE 1078 3-93.1.3 Red Hat® Enterprise Linux OSTo install the RAID card driver when installing Red Hat Red Hat® Enterprise OS:1. Boot the syste

Page 76

3-10 Chapter 3: Driver installation6. When asked if you will load additional RAID controller drivers, select No, then press <Enter>.5. Insert

Page 77 - Enterprise Linux OS

ASUS PIKE 1078 3-113.1.4 SUSE Linux Enterprise Server OSTo install the RAID card driver when installing SUSE Linux Enterprise Server OS: SUSE Linux E

Page 78

1-2 Chapter 1: Product introduction1.1 Welcome!Thank you for buying an ASUS® PIKE 1078 SAS RAID card! The ASUS PIKE 1078 allows you to create RAID 0,

Page 79

3-12 Chapter 3: Driver installation4. Insert the RAID driver disk to the oppy disk drive. Make sure that Installation from the Boot Options menu is

Page 80

ASUS PIKE 1078 1-31.3 Card layoutThe images below show the major components of the RAID card.1.4 System requirementsBefore you install the PIKE 1078

Comments to this Manuals

No comments