ASUS PIKE 1078 2-11
8. Check the information in the conguration preview.
9. If the virtual disk conguration is acceptable, click Accept to save the
conguration. Otherwise, click Cancel to end the operation and return to the
WebBIOS main menu, or click Back to return to the previous screens and
change the conguration.
10. If you accept the conguration, click Yes at the prompt to save the
conguration.
The WebBIOS main menu appears.
Using Custom Conguration: RAID 1
In RAID 1, the RAID controller duplicates all data from one drive to a second
drive. RAID 1 provides complete data redundancy, but at the cost of doubling the
required data storage capacity. It is appropriate for small databases or any other
environment that requires fault tolerance but small capacity.
When you select Custom Conguration and click Next, the Disk Group Denition
screen appears. You use this screen to select physical drives to create disk groups
(arrays).
1. Hold <Ctrl> while selecting two
ready physical drives in the Physical
Drives window on the left.
2. Click Accept DG to move the
drives to a proposed disk group
conguration in the Disk Groups
window on the right, as shown in
the right gure.
If you need to undo the changes,
click the Back button.
Comments to this Manuals