10.3.3 Measurement Result
EGSM900 Ch62 DCS1800 Ch700
Pay attention to this value only for confirming whether the component is normal, does not
represent real power value.
From reading the value, we can judge from it whether their wave
and relative value are correct or not. In accordance with the
specifications of the probe used, the value of measurement is also not
the same.
First, waveforms must be a normal bust, and low band should
higher than high band about 1dB. This can only be confirmed TR switch
is in normal operation, not guarantee PA normal operation in SKY77513.
Need to confirm the value of Vapc, to find that FEM or TR is
problematic.