2-12 Chapter 2: BIOS information
DRAM READ to WRITE Delay(DD) [Auto]
Conguration options: [Auto] [2 DRAM Clock] – [14 DRAM Clock]
DRAM READ to WRITE Delay(DR) [Auto]
Conguration options: [Auto] [2 DRAM Clock] – [14 DRAM Clock]
DRAM READ to WRITE Delay(SR) [Auto]
Conguration options: [Auto] [2 DRAM Clock] – [14 DRAM Clock]
DRAM READ to READ Delay(DD) [Auto]
Conguration options: [Auto] [2 DRAM Clock] – [9 DRAM Clock]
DRAM READ to READ Delay(DR) [Auto]
Conguration options: [Auto] [2 DRAM Clock] – [9 DRAM Clock]
DRAM READ to READ Delay(SR) [Auto]
Conguration options: [Auto] [4 DRAM Clock] [6 DRAM Clock]
DRAM WRITE to WRITE Delay(DD) [Auto]
Conguration options: [Auto] [2 DRAM Clock] – [9 DRAM Clock]
DRAM WRITE to WRITE Delay(DR) [Auto]
Conguration options: [Auto] [2 DRAM Clock] – [9 DRAM Clock]
DRAM WRITE to WRITE Delay(SR) [Auto]
Conguration options: [Auto] [4 DRAM Clock] [6 DRAM Clock]
CPU Voltage Mode [Offset]
Allows you to set the CPU voltage mode.
Conguration options: [Offset] [Manual]
Offset Voltage [Auto]
Allows you to set the offset voltage.Use the <+> and <-> keys to adjust the value.
Conguration options: [Auto] [Max.=0.30000V] [Min.=0.01000V]
IMC Voltage [Auto]
Allows you to set the CPU Integrated Memory Controller voltage. Use the <+> and <-> keys
to adjust the value. Conguration options: [Auto] [Max.=1.39V] [Min.=1.10V]
DRAM Voltage [Auto]
Allows you to set the DRAM voltage. Use the <+> and <-> keys to adjust the value.
Conguration options: [Auto] [Max.=1.8V] [Min.=1.5V]
PCH Voltage [Auto]
Allows you to set the Platform Controller Hub voltage. Conguration options: [Auto]
[Max.=1.15V] [Min.=1.05V]
The values of the IMC Voltage and DRAM Voltage Voltage items are labeled in different
color, indicating the risk levels of high voltage settings.
The system may need better cooling system to work stably under high voltage settings.