Asus DS300f User Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
36
ASUS Storage DS300j User Manual
4. Do one of the following actions:
Click the Download Flash File from TFTP Server option, then click the
Next button.
Click the Download Flash File from Local File through HTTP option,
then click the Next button.
5. For the TFTP Server option:
Enter the hostname or IP address of your TFTP server in the field
provided.
Enter the port number of your TFTP server in the field provided (69 is
the default).
Enter the filename of the Firmware Update file in the field provided. The
filename is similar to exp.fw.2.03.0000.00.bin.
Click the Submit button.
For the Local File option:
Click the Browse button.
Navigate to the Firmware Update file. The filename is similar to
exp.fw.2.03.0000.00.bin.
Click the file, then click the Open button.
Click the Submit button.
6. When the download is completed, click the Next button.
A popup message appears warning you not to reboot the ASUS Storage
during the firmware update procedure.
7. In the popup message, click the OK button.
The update progress displays. Then a popup message appears to tell you to
reboot the ASUS Storage.
8. In the popup message, click the OK button.
9. Restart the DS300F or DS300I subsystem and the DS300j units:
Shut down the DS300F or DS300I subsystem. See the ASUS Storage
DS300F, DS300I User Manual.
On the ASUS Storage DS300j units, turn OFF the power supply
switches. See page 37, Figure 1.
Wait 30 seconds, then turn ON the DS300j units power supply
switches.
Wait 30 additional seconds, then turn ON the DS300F or DS300I
subsystems power supply switches.
Page view 39
1 ... 39 40 41 ... 56

Comments to this Manuals

No comments