ASUS ASMB6-iKVM 4-15
Procedure:
1. Click the Event Filter Tab to congure the event lters in the available slots
2. To Add an Event Filter entry, select a free slot and click
Add to open the Add
event Filter entry Page. A sample screenshot of Add Event Filter Page is in
seen the screenshot below.
3. In the Event Filter Conguration section,
• PEF ID displays the ID for congured PEF entry (read-only).
• In lter conguration, check the box to enable the PEF settings.
• In Event Severity, select any one of the Event severity from the list.
4. In the Filter Action conguration section,
• Event Filter Action is a mandatory eld and checked by default, which enable
PEF Alert action (read-only).
• Select any one of the Power action either Power down, Power reset or Power
cycle from the drop down list
• Choose any one of the congured alert policy number from the drop down
list.
Alert Policy has to be congured - under Conguration->PEF->Alert Policy.
5. In the Generator ID conguration section,
• Check Generator ID Data option to ll the Generator ID with raw data.
• Generator ID 1 eld is used to give raw generator ID1 data value.
• Generator ID 2 eld is used to give raw generator ID2 data value.
In RAW data eld, to specify hexadecimal value prex with '0x'.
Comments to this Manuals