Asus RS160-E4/PA4 User Manual Page 153

  • Download
  • Add to my manuals
  • Print
  • Page
    / 186
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 152
ASUS RS160-E4/PA4 6-39
6.3.8 Rebuilding the RAID
This option is only for the RAID 1, RAID 5 and RAID 10 level.
Rebuilding the RAID with other non-RAID disk:
1. If one member of physical SATA Hard disk within the array is off-line or failed,
the status of array will become to be degraded from normal. The following
displays as:
2. Press <Ctrl-I> to enter the Intel Matrix Storage Manager RAID conguration
utility after POST.
3. If there is available Non-RAID SATA Hard Disk, the utility will prompt
the windows for rebuilding the RAID. Press <Enter> to select the port of
destination disk for rebuilding or press <ESC> to exit
The size of destination disk for rebuilding should be the same or bigger as the
original hard disk.
Page view 152
1 ... 152 153 154 ... 186